Nov 14, 2025 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Sep 23, 2024 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Jan 17, 2020 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Dec 28, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 14, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 19, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 19, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Sep 29, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY W/COMMISSIONERS ORDER#327894 ISSUED ON 4/26/16 TO RETAIN A NYS PE ENG'R TO PREP SHORING DWGS FOR EXISTING FRAMING BET 2ND TO SUB CELLAR FLRS&OBTAIN PERMITS NO LATER THAN 5/24/16.PERMITS HAVE NOT BEEN OBTAINED AS OF 9/29/16.REMEDY:COMPLY WITH COMMISSIONERS ORDER#327894 IMMEDIATELY
Sep 29, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY W/COMMISSIONERS ORDER#327893 ISSUED ON 4/26/16 TO PROVGIDE A STRL ENG'R ASSESSMENT REPORT OF THE STRL STABILITY OF THE BLDG&THE SHORING PRODUCED BY A LIC NYS PE NO LATER THAN 5/10/16.REPORT HAS NOT BEEN OBTAINED AS OF 9/29/16.REMEDY:COMPLY WITH COMMISSIONERS ORDER#327893 IMMEDIATELY
Sep 29, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY W/COMMISSIONER ORDER#327895 ISSUED ON 4/26/16 TO RETAIN A NYS PE ENG'R TO PREP PERM SUPPORT&REINFORCEMENT OF THE EXISTING FRAMING BET 2ND TO SUB CELLAR FLRS&OBTAIN PERMITS NO LATER 6/7/16.PERMITS HAVE NOT BEEN OBTAINED AS OF 9/29/16.REMEDY:COMPLY W/ COMMISSIONER ORDER#327895 IMMEDIATELY
Jun 28, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY W/COMMISSIONERS ORDER VIO#042616FEU50103MM.CONTROL NO.327895 REQUIRES THE OWNER TO FILE PERMANENT REPAIR DWGS BY 5/24/16 W/WORK TO COMMENCE BY 6/7/16 UNDER PERMIT ON 6/28/16 NO PERMIT HAS BEEN FILED.REMEDY:IMMED COMPLY W/COMMISSIONERS ORDER CONTTROL#327895 FILED DWGS BY 7/16/16.WORK TO COMMENCE BY 7/13/16
May 12, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY W COMMISSIONERS ORDER VIO#042616 FEU50102MM CONTROL# 327894 REQUIRES THE OWNER TO FILE TEMP SHORING DRAWINGS BY 5/10/16 AS OF 5/12/2016 NO JOBS HAVE BEEN FILED W DOB. REMEDY: IMMEDIATELY COMPLY TO COMISSIONERS ORDER VIO #042613 FEU50102MM, CONTROL#327894
May 12, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY WITH COMMISSIONERS ORDER:VIO#042616 FEU2010MM CTRL#327893 REQUIRES THE OWNER TO HIRE A NYS PE TO ASSES THE BLDG & SUBMIT A SIGNED&SERVED REPORT BY 5/10/16. AS OF 5/12/16 NO REPORT HAS BEEN RECIVED BY DOB. REMEDY:IMMEDIATELY COMPLY W COMMISSIONERS ORDER VIO#042616 FEU50101MM CTRL#327893
Apr 26, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FM.THE BLDG HAS UNDERGONE INTERIOR CHANGES IN THE 1FLR CELLAR & SUB CELLAR IN 1993 UNDER PERMIT. THE WALL REMOVAL MAY HAVE CONTRIBUTED TO THE SIGNIFICANTLY DEFLECTING 1FLR FRAMING.THE BLDG REQUIRES PERMANENT STRUCTURAL REPAIRS. REMEDY:RETAIN A NYS LIC PE TO PREPARE PERMANENT SUPPORT&REINFORCEMENT. DWGS TO B/FILED W/DOB BY 5/24/16
Apr 26, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FM.THE BLDG HAS UNDERGONE INTERIOR WALL CHANGES IN THE FST FL CELLAR & SUB CELLAR IN 1993 UNDER PERMIT. THE WALL REMOVAL MAY HAVE CONTRIBUTED TO THE SIGNIFICANLTY DEFLECTING 1FLR FRAMING.SHORING WAS PLACED W/OUT PERMIT BTWN THE 1FLR & CELLAR. REMEDY:RETAIN NYS LIC PE TO PREPARE DWGS FOR EXISTING FRAMING BTWN 2FL&SUB CELLAR FILE W/DOB BY 5/10/16
Apr 26, 2016 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FM.THE BLDG HAS UNDERGONE INTERIOR WALL CHANGES IN THE 1FLR CELLAR & SUB CELLAR IN 1993 UNDER PERMIT.THE WALL REMOVAL MAY HAVE CONTIBUTED TO THE SIGNIFICANTLY DEFLECTING CONDITION OF THE 1FLR FRAMING.REMEDY: PROVIDE A STRUCTURAL ENGINEERING ASSESSMENT REPORT OF THE STRUCTURAL STABILITY OF THE BLDG.REPORT TO BE SUBMITTED TO DOB FEU BY 5/10/16
Mar 3, 2015 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Jan 15, 2014 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jul 19, 1994 VP*-VIOLATION UNSERVED ECB- DISMISSED C-CONSTRUCTION OTHER OPTIONAL H
Aug 12, 1993 VPW*-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL