| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Nov 8, 2019 | I | VIOLATION DISMISSED | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Jul 15, 2016 | I | VIOLATION DISMISSED | Not available | SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Jul 13, 2016 | C | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF COLLAPSING DROP-CEILING TILES IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | C | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR-BELL AT FRONT ENTRANCE TO IN THE FOYER LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE VINYL SIDING AT NORTH AND WEST SECTION OF EXTERIOR BUILDING , 2nd STORY |
| Jul 16, 2015 | A | NOV SENT OUT | Not available | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING VINYL TILES AT WOOD FLOOR AT VESTIBULE AT PUBLIC HALL, 1st STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AT CERAMIC TILES WALLS AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE CERAMIC TILES AT WALLS AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER-TOP AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR INSIDE BASE-CABINETS UNDER SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD AND VINYL TILES FLOOR IN THE KITCHEN LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY |
| Jul 16, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING AT PUBLIC HALL, 1st STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FRAME AT ENTRANCE DOOR LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY |
| Jul 16, 2015 | B | NOV SENT OUT | 2 | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). '' MISSING '' IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY |
| Jun 17, 2015 | A | NOV SENT OUT | Not available | SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE DEBRI AT FRONT YARD |
| May 7, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2073 ADM CODE - DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE GAS PIPE FOR THE STOVE AT CELLAR |
| May 7, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES WHERE ILLEGAL AND PROPERLY SEAL PIPE CONNECTIONS BATHROOM, SHOWER AND WASHBASIN AT CELLAR |
| May 7, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE DEBRI AT AT CELLAR |
| May 7, 2015 | C | VIOLATION CLOSED | Not available | SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE DEBRI AT SOUTH YARD |
| May 7, 2015 | B | NOV SENT OUT | 1 | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY |
| May 7, 2015 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY |
| May 7, 2015 | B | NOV SENT OUT | 1 | SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY |
| May 7, 2015 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY |
| Apr 22, 2015 | B | NOV SENT OUT | Not available | SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE DEBRI AT FRONT NORTH YARD |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ''MISSING'' IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER-TOP AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | Not available | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY |
| Aug 21, 2013 | B | NOV SENT OUT | Not available | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING AT PUBLIC HALL, 1st STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | B | NOV SENT OUT | 2 | SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES ( NO VOLUME ) AT BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY |
| Aug 21, 2013 | C | NOV SENT OUT | 2 | SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY |