Queens Pomonok-Electchester-Hillcrest
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
203 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Dec 2, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 2, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 2, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 2, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 21, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 26, 2002 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 26, 2002 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Dec 11, 2001 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 4P2749 |
| Feb 27, 2001 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 27, 2001 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 27, 2001 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 7, 2000 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 7, 2000 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 16, 1999 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 16, 1999 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 4, 1998 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Oct 8, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 23, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 7, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 7, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 28, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 28, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Dec 27, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)IN CAB CAPACITY PLATE 2000LBS.(15)DUST COVERS PROVIDE WHERE MISSING.(30)ELECTRIC BOX COVERS 6TH FLOOR |
| Dec 27, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)IN CAB CAPACITY PLATE 2000LBS PROVIDE.(35)GLASS TO WINDOW BROKEN.(15)DUST COVERS PROVIDE (MISSING) |
| Nov 27, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (35)REMOVE OUT SIDE LIGHTING TO ROOF CONNECTED TO MAIN LINE SWITCH IN MR, REPLACE HANDLE MISSING TO MR DOOR, POST ELEVATOR CO SIGN (62)ELECTRIC BOX COVERS (17)CAR GLASS (15)DUST COVERS |
| Nov 14, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (01)REPLACE BUTTON.(15)1 FLOOR DUST COVER.(35)POST ELEVATOR CO SIGN,CLEAN ROOM & REMOVE STORAGE,REPLACE BROKEN GLASS TO WINDOW.(39) REMOVE CABLE SLIPPAGE TO SAME 53 & 54 REMOVE FROM MAIN LINE SWITCH & MOTOR ROOM LIGHTS ROOF LINE TAPS.(03)SECURE & PROVIDE ALL CAR TOP ELEC BOX COVER,CLEAN CAR TOP,PROVIDE IN CAB CAP. PLATE 2000LBS |
| Nov 14, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)DUST COVER BSMT.(35)CLEAN ROOM & REMOVE STORAGE,POST ELEVATOR COMPANY SIGN,REPLACE BROKEN GLASS TO WINDOW. 53 & 54 REMOVE ROOF LINE TAPS FROM SAME.(03)CLEAN CAR TOP,PROVIDE IN CAB CAPACITY PLATE 1800LBS |
| Oct 26, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)IN CAB CAPACITY PLATE 2000LBS.(03)CLEAN CAR TOP.(35)POST ELEV COMPANY SIGN.(53)SECURE MOTOR ROOM LIGHT SWITCH & COVER TO ELECTRIC BOX.(53)REMOVE ROOF LIGHT LINE TAPED TO MOTOR ROOM LIGHTING.(37)REPAIR OVERLOAD ON CONTROLLER |
| Oct 26, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)IN CAB CAPACITY PLATE 2000LBS.(15)PROVIDE MISSING DUST COVERS (03)CLEAN CAR TOP.(62)UNDER CAR LIGHT.(35)REPLACE BROKEN GLASS TO WIND OWS,POST ELEVATOR COMPANY SIGN.(53 & 54)REMOVE ROOF TAP TO BOTH ELECTR LINES |
| Oct 17, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (14)PLASTIC & SET SCREW TO FRAIM (03)PROVIDE IN CAB CAPACITY PLATE 2000LBS AND CLEAN CAR TOP (35)SECURE SMOKE HOLE GRATE, REPLACE BROKEN GLASS TO WINDWS,REMOVE ALL NON ELEVATOR STORAGE AND CLEAN ROOM & OIL ON FLOOR (52)RELINE OIL SOAKED SHOES (54)ROOF TAP REMOVE (39) CABLE SLIPPAGE |
| Oct 17, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)DUST COVERS MISSING (35)REPLACE BROKEN GLASS TO WINDOWS,CLEAN ROOM,CLEAN OIL MAIN MAHINE & FLOOR OF MR (21)HALL INDICATORS (46)SHACKEL SPRINGS BROKEN CWT (03)REPLACE MISSING IN CAB CAPACITY PLATE 2000LBS, AND CLEAN CAR TOP |
| Oct 12, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)PROVIDE DUST COVERS MISSING (35)REPLACE BROKEN GLASS TO MR WINDOW (53)REMOVE ROOF LIGHTING FROM MR LIGHTING LINE (04)REMOVE ROOF TOP OFF FROM MAIN LINE SWITCH (03)PROVIDE 200LBS CAPACITY PLATE IN CAB (74)CLEAN CAR TOP |
| Oct 10, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)PROVIDE MISSING DUST COVERS (40)TO FLOOR SECURE PROPERLY (03)PROVIDE IN CAB 2000LBS CAPACITY PLATE (62)SECURE ELECTRIC BOX COVERS AND CLEAN UNDER CAR (21)6TH FL HALL INDICATOR LIGHTS (53)REMOVE ROOF LIGHT TAP TO MR LIGHTING LINE |
| Oct 10, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)DUST COVERS MISSING (11)BELL SOUND (03)IN CAB 2000LBS CAPACITY PLATE (03)PROPERLY PIPE AND WIRE CAR TOP FAN AND PROVIDE MISSING CAB WALL SKINS (35)REPLACE GLASS BROKEN WINDOW, REMOVE ROOF TAP FLOOR CONTROLLER |
| Oct 3, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)PROVIDE ALL MISSING DUST COVERS AS NECESSARY (14)PROVIDE FRAME AND A 2000LBS CAPACITY PLATE IN CAB (21)BASEMENT FLOOR INDICATOR REPAIR 1 & 5 LIGHTS (35)PROVIDE SMOKE HOLE GRATE MISSING, POST ELEV CO SIGN, REPLACE BROKEN GLASS TO WINSOWS, REMOVE LINE TAP FROM M.R TO ROOF, REMOVE ALL NOW ELEVATOR STORAGE |
| Oct 3, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)DUST COVERS AS NEEDED (16)PROVIDE FRAME AND CAPACITY PLATE 2000LBS IN CAB (35)REPLACE BROKEN GLASS M.R WINDOW, POST ELEV CO SIGN, REMOVE LINE ATTACHED TO MOTOR ROOM LIGHTING FOR ROOF LIGHT, AND REMOVE TAP OFF OF MAIN LINE SWITCH FOR ROOF WORK |
| Oct 2, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 18-COVER BSMT 35-CLEAN ROOM, POST ELEVATOR CO SIGN & REPLACE BROKEN GLASS TO WINDOW.54-ROOF TAP CONECTED TO CONTROLLER.62-SECURE & PROVIDE ELECTRIC BOX COVERS & REPAIR LIGHT.15-PROVIDE MISSING DUST COVERS.03-CLEAN CAR TOP |
| Sep 22, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (21)HALL INDICATOR PLATES MISSING PROVIDE (35)PROPERLY SECURE HAND RAIL AT TOP OF STEP (35)REPLACE DAMAGED GLASS TO WINDOW (03)PROVIDE 2000LBS CAPACITY PLATE IN CAB (54)REMOVE CABLE ELECTRICAL TO ROOF (15)DUST COVERS |
| Jul 21, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (05)ELIMINATE ROPE SLIPPAGE |
| Jul 21, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (34)CAR DOOR GIBS.(45)REMOVE WATER.(51)REPLACE MAIN LINE BOX COVER IN MOTOR ROOM |
| Jul 21, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (34)CAR DOOR GIB.(43)ELIMINATE EXCESSIVE PLAY |