| Date | Status | Type | Summary |
|---|---|---|---|
| Sep 22, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 22, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 22, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 22, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 22, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 22, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Apr 17, 1995 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Mar 22, 1995 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jun 7, 1994 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 31, 1994 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| May 31, 1994 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Jun 28, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 28, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 10, 1991 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | DEVICE #4P2583 |
| Mar 22, 1990 | VP-VIOLATION UNSERVED ECB-ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | JD |
| Nov 27, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (08)FLOOR STOP ADJUST (25)COVER (35)REPLACE GLASS BROKEN TO WINDOWS & PROVIDE ACCESS INTO MOTOR ROOM (03)PROVIDE IN CAB CAPACITY PLATE 2000 LBS , PROPERLY PIPE AND WIRE CAB VENT FAN ON CAR TOP & PROVIDE GUARD TO FAN CAR TOP , CLEAN CAR TOP |
| Nov 14, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)DUST COVERS 1 FLOOR & 5TH FLOOR.(35)POST ELEVATOR COMPANY SIGN & REPLACE BROKEN GLASS TO MOTOR ROOM WINDOWS.(03)PROVIDE 2000LBS IN CAB CAPACITY PLATE,PROPERLY PIPE & WIRE CAB VENT FAN AND PROVIDE GUARD FOR SAME TOP OF CAR |
| Oct 12, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)PROVIDE IN CAB CAPACITY PLATE 2000 LBS (35)POST ELEV CO SIGN REPLACE BROKEN GLASS TO MR WINDOW,REPAIR LIGHTING & REMOVE NON ELEV STORAGE (37)REMOVE ROOF TAP LINE (03)PROVIDE CAB WALL VENT GRILL & REO PEN SAME IN CAB (74)PROPERLY PIPE & WIRE CAB BENT FAN,AND CLEAN CAR TOP, PROVIDE GUARD TO VENT FAN ON CAR TOP |
| Oct 10, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (15)DUST COVERS MISSING (03)PROVIDE IN CAB 2000LBS CAPACITY PLATE (35)REMOVE STORAE IN MOTOR ROOM AND REMOVE ROOF TAP ON CONTROLLER (50)RENEW NOISE TO MACHINE (53)PROPERLY PIPE AND WIRE MR. LIGHTING FIXTURES |
| Oct 2, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 02-BELL SOUND 03-PROVIDE 2000LBS CAPACITY PLATE MISSING AND ISSIN MISSING CAB WALL SKINS 03-PROPERLY WIRES & PIPE CAB FAN ON CAR TOP, PROVIDE FAN GUARD CAR TOP, & CLEAN CAR TOP 35-CLEAN ROOM,POST ELEVATOR CO SIGN,REPLACE BROKEN GLASS TO WINDOWS,& REMOVE TAP FOR ROOF CONECTED TO CONTROLLER 53-PROPERLY WIRE & PIPE MOTOR ROOM LIGHTING |
| Oct 2, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 03-FAN GUARD REPLACE IN CAB, PROVIDE PROPER GUARD TO TOP OF CAR & PROPERLY PIPE & WIRE FAN ON CAR TOP,CLEAN CAR TOP 35-POST ELEV CO SIGN IN MR,REMOVE ALL NON ELEV STORAGE,REPLACE GLASS BROKEN TO WINDOWS 39- REMOVE CABLES SIPPAGE 37-REMOVE ROOF TAP CONECTED TO CONTROLLER 03-PRO VIDE 2000LBS CAPACITY PLATE IN CAB 15-DUST COVERS |
| Sep 21, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)PROVIDE 2000LBS CAPACITY PLATE IN CAB (35)REMOVE ELECTRIC CABLE TO ROOF CONNECTED TO CONTROLLER (35)REPLACE GLASS BROKEN IN WINDOWS (53)PROPERLY WIRE AND PIPE M.R LIGHTING (74)CLEAN CAR TOP AND PROVIDE CAB FAN GUARD TOP OF CAR |
| Sep 21, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (06)PROVIDE COVERS TO GATE SW (14)PROVIDE IN CAB CAPACITY PLATE 2000LBS AND CERTIFICATE FRAME (37)REMOVE CABLE CONNECTED TO CONTROLLER FOR ROOF WORKER (35)REPLACE GLASS BROKEN TO WINDOW (59)PROPERLY PIPE AND WIRE MR LIGHTING (74)PROVIDE FAN GUARD TOP OF CAR AND CLEAN SAME (74B)CLEAN CAR TOP |
| Sep 19, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (07)SAFTEY EDGE |
| Jul 18, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (05)ELIMINATE ROPE SLIPPAGE.(43)ELIMINATE EXCESSIVE PLAY BETWEEN CAR & RAILS.(51)REPAIR OR RENEW CAR FLOORING |
| Jul 18, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (28 & 29)ELIMINATE EXCESSIVE OIL LEAK & CLEAR AREA AROUND MAIN MACHINE.(51)REPLACE BROKEN SHACKLE SPRING ON CROSSHEAD |
| Jul 18, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (29)ELIMINATE EXCESSIVE NOISE |
| Jul 18, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (29)ELIMINATE EXCESSIVE NOISE.(43)ELIMINATE EXCESSIVE PLAY.(51) RENEW BROKEN SHACKLE SPRING ON CROSSHEAD |