NYC Building Report

Queens Corona

98-23 Horace Harding Expressway, Queens

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

64 records

Date Status Type Summary
Feb 10, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (51)REPAIR ALL FIRE RELATED DAMAGE AND WATER DAMAGE AS WHERE NECESSARY TO PASS 4480 AND ALL HOISTWAY EQUIPMENT (52)CLEAN INSIDE OF CARS CEILING AND REPAIR SAME (53)CLEAN CAR TOP
Feb 10, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (51)REPAIR ALL FIRE AND WATER RELATED DAMAGE AS WHERE NECESSARY TO PASS 4481 AND ALL HOIST WAY EQUIPMENT (52)CLEAN CAR TOP
Feb 10, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (51)REPAIR ALL FIRE AND WATER RELATED DAMAGE AS WHERE NECESSARY TO PASS 4482 AND ALL HOIST WAY EQUIPMENT (52)CLEAN CAR TOP
Feb 10, 1989 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL MP
Feb 10, 1989 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL M.P
Jan 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 51)RE3PLACE MISSING DUST COVERS IN HOISTWAY 52)HAVE CAR PROPERLY ANSWER 2L CAR CALL 53)RENEW BROKEN SHACKLE SPRINGS ON CWT FRAME 54)REPAIR BROKEN WINDOW IN MOTOR ROOM
Jan 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 51)REPLACE ALL MISSING DUST COVERS IN HOISTWAY 52)PROVIDE LIGHT GUARDS IN CAR 52)REPAIR LIGHT ON TOP OF CAR
Jan 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 51)PROVIDE LIGHT GUARDS IN CAR 52)RENEW BROKEN SHACKLE ON CAR FRA FRAME 53)REPLACE ALL MISSING DUST COURSE IN HOISTWAY 54)REPAIR LIGHT ON TOP OF CAR
Jan 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 51-REPLACE MISSING DUST COVERS IN HOISTWAY 52-PROVIDE LIGHT ON TOP OF CAR
Jan 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 51-REPLACE ALL MISSING DUST COVER IN HOSITWAY
Jan 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 51-PROVIDE LIGHT GUARD IN CAR 52-REPAIR BROKEN WINDOW IN MOTOR ROOM 53-GAUT OPENING BETWEEN WINDOW FRAME AND MOTOR ROOM WALL
Sep 28, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (15) SECURE (33) PROVIDE MISSING DUST COVERS AND MAKE DOORS SELF CLOSING. (51) PROVIDE FAN GUARD AND REPAIR WORK LIGHTS IN PIT TOP AND BOTTOM OF CAR PROPERLY ENCLOSE WIRES ON TOP OF CAR
Sep 28, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 15)SECURE 33)PROVIDE MISSING DUST COVER AND MAKE DOORS SELF CLOSING 47)REPAIR DOOR AND WATERR.PROOF WINDOWS 51)PROVIDE FAN GUARD A AND WORK LIGHTS IN PIT,TOP AND BOTTOM OF CAR ,PROPERLY ENCLOSE WIRES ON TOP OF CAR
Sep 28, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 15)SECURE .33)PROVIDE MISSING DUST COVERS AND MAKE DOORS SELF CLOSING 51)PROVIDE FAN GUARD,AND REPAIR WORK LIGHTS IN PIT,TOP AND BOTTOM OF CAR,PROPERLY ENCLOSE WIRES ON TOP OF CAR