| Date | Status | Type | Summary |
|---|---|---|---|
| Feb 9, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY W/COMMISSIONER'S ORDER:DOB VIOLATION #122625FEU40302AK (CONTROL#350407)WHICH REQUIRES OWNER ENGAGE A NYS PE &ENDRSD CNTRCTR TO EVAL THE ENTIRE BLDG&REPAIR OR DEMO THE BLDG UNDER PERMIT W/PERMITS FILED FOR BY 1/30/26.AS OF 2/9/26,NO REPAIR OR DEMO JOBS HAVE BEEN FILED.COMPLY W/COMMISSIONER'S ORDER |
| Feb 9, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #122625FEU40301AK (CONTROL #350406) WHICH REQUIRES OWNER ENGAGE A NYS PE&ENDRSD CNTRCTR TO EVALUATE THE ENTIRE BLDG&REPAIR OR DEMOLISH THE BUILDING UNDER PERMIT WITH PERMITS FILED FOR BY 1/30/26.AS OF 2/9/26, NO REPAIR OR DEMO JOBS HAVE BEEN FILED.COMPLY W/COMMISSIONER'S ORDER |
| Dec 26, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM-AT TIME OF INSPECTION OBSVD BLDG TO BE IN A STATE OF DISREPAIR W/ FIRE,WATER, & SMOKE DAMAGE THROUGHOUT.ROOF OPEN & ROOF JOIST CHARRED, EXP3 WALL CHARRED, WINDOWS OUT.OWNER TO ENGAGE A NYSPE ENDORSED CONT'R TO EVAL ENTIRE BLDG REPR OR DEMOLISH UNDER PERMIT,FILE FOR PERMIT BY 1/30/26 |
| Dec 26, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM-AT TIME OF INSPECTION OBSVD BLDG TO BE IN A STATE OF DISREPAIR W/ FIRE,WATER & SMOKE DAMAGE THROUGHOUT.ROOF OPEN & ROOF JOIST CHARRED, EXP3 WALL CHARRED,WINDOWS OUT.OWNER TO ENGAGE NYSPE ENDORSED CONT'R TO EVAL ENTIRE BLDG& REPR OR DEMOLISH UNDER PERMIT,FILE FOR PERMIT BY 1/30/26 |
| Dec 26, 2025 | V%-DOB VIOLATION | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |
| Dec 26, 2025 | V-DOB VIOLATION - ACTIVE | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |
| Dec 26, 2025 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | REMEDY: SEAL ALL FIRE DAMAGED AND ACCESSIBLE OPENINGS TO PROTECT THE PUBLIC AND PROPERTY AND PREVENT UNAUTHORIZED ENTRY |
| Dec 26, 2025 | V-DOB VIOLATION - ACTIVE | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | REMEDY: SEAL ALL FIRE DAMAGED AND ACCESSIBLE OPENINGS TO PROTECT THE PUBLIC AND PROPERTY AND PREVENT UNAUTHORIZED ENTRY |
| Dec 25, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | STRUCTURE RENDERED NONCOMPLIANT DUE TO FIRE THAT LEFT ROOF, BLDG UNSAF E TO OCCUPY DUE TO COMPROMISED ROOF REMEDY: VACATE STRUCTURE, SEAL PUBLIC OPENINGS |