| Mar 2, 2013 | C | VIOLATION CLOSED | Not available | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM AT CELLAR |
| Mar 2, 2013 | C | VIOLATION CLOSED | 11C | SECTION 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 11C, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Apr 2, 2012 | A | VIOLATION CLOSED | 2A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE 1st BEDROOM FROM NORTH LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Feb 12, 2012 | B | VIOLATION CLOSED | 6B | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 20, 2011 | B | VIOLATION CLOSED | 4B | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILNG IN THE 4th ROOM FROM EAST LOCATED AT APT 4B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 23, 2011 | B | VIOLATION CLOSED | 11C | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 11C, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Mar 8, 2011 | C | NOV SENT OUT | 11C | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) DOOR FROM WEST AT NORTH WALL, RISER FROM NORTH AT EAST WALL IN THE BATHROOM LOCATED AT APT 11C, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Mar 8, 2011 | B | VIOLATION CLOSED | 11C | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER SASH COUNTER BALANCE WINDOW IN THE KITCHEN LOCATED AT APT 11C, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Oct 18, 2010 | C | INVALID CERTIFICATION | 11C | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) NORTH WALL IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 11C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 18, 2010 | C | INVALID CERTIFICATION | 11C | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 11C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 18, 2010 | C | INVALID CERTIFICATION | 11C | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL, NORTH WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 11C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 18, 2010 | C | INVALID CERTIFICATION | 11C | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 11C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 6, 2010 | B | VIOLATION CLOSED | 4B | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR , DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 10, 2010 | A | VIOLATION CLOSED | 11C | SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION .. 1st RADIATOR FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 11C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Nov 10, 2004 | B | NOV CERTIFIED LATE | 1A | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jul 3, 2002 | B | NOV SENT OUT | Not available | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS bathtub and water closet in the bathroom area. , CELLAR |
| Jul 3, 2002 | B | NOV SENT OUT | Not available | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE glass north and south windows , CELLAR |
| Jul 3, 2002 | B | NOV SENT OUT | Not available | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE metal ceiling AT BOILER ROOM, CELLAR |
| Jul 27, 2001 | B | VIOLATION CLOSED | 2A | SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY |
| Aug 28, 1999 | C | VIOLATION CLOSED | 1 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK ENTRANCE DOOR TO APT 1 STY APT 2A. , SECTION '' '' |
| May 29, 1999 | B | VIOLATION CLOSED | 2A | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CEILING 1 STY APT 2A KITCHEN. , SECTION '' '' |
| Apr 16, 1998 | A | VIOLATION CLOSED | C11 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING THTUOUT 3 STY NORTH APT C11. , SECTION '' '' |
| Apr 16, 1998 | C | VIOLATION CLOSED | C11 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW WEST WALL BATHROOM 3 STY NORTH APT C11. , SECTION '' '' |
| Apr 16, 1998 | C | VIOLATION CLOSED | C11 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW WEST WALL 3 STY NORTH ROOM APT C11. , SECTION '' '' |
| Apr 16, 1998 | C | VIOLATION CLOSED | C11 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW WALLS NORTH WALL NORTH ROOM 3 STY APT C11. , SECTION '' '' |
| Jun 30, 1997 | B | VIOLATION CLOSED | 7B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERIOR MOLDING AT DOOR ENTRANCE 2 STY SOUTHWEST APT 7B. , SECTION '' '' |
| Jun 30, 1997 | B | NOT COMPLIED WITH | Not available | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS SOUTHWEST CELLAR. |
| Jun 30, 1997 | A | VIOLATION CLOSED | 1 | SECTION 27-2005 ADM CODE REFIT ENTRANCE DOOR 1 STY NORTH APT 1. LOCATED AT APT 1 |
| Jun 30, 1997 | B | VIOLATION CLOSED | 6 | SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 2 STY SOUTHWEST APT 6. LOCATED AT APT 6 |
| Jun 30, 1997 | B | NOT COMPLIED WITH | Not available | SECTION 242 M/D LAW PROVIDE UNDER COMPLETED PERMIT,A PROPER ENCLOSURE WITH FIREPROOF SELFCLOSING DOORS AND ASSEMBLIES,AT THE TOP AND THE BOTTOM OF THE CELLAR STAIRS, EAST CELLAR STAIRS TO 1ST STY EXIT DOOR. |
| Jun 7, 1996 | B | VIOLATION CLOSED | 2A | SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE 1 STY APT 2A SINK KITCHEN. , SECTION '' '' |
| Jun 7, 1996 | B | NOV CERTIFIED LATE | 2A | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 1 STY APT 2A MS DOUGLAS. , SECTION '' '' |
| Jun 7, 1996 | B | VIOLATION CLOSED | 2A | SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE ROACHES 1 STY APT 2A KITCHEN. , SECTION '' '' |
| Jun 7, 1996 | A | VIOLATION CLOSED | 2A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT INTERIOR AREA OF WOODEN WINDOW FRAME 1 STY APT 2A KITCHEN. , SECTION '' '' |
| Jun 7, 1996 | B | VIOLATION CLOSED | 2A | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN 1 STY APT 2A BATHROOM. , SECTION '' '' |