Queens North Corona
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 4-01715-0027), so they can include other buildings on the same lot.
29 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jun 12, 2025 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Apr 15, 2024 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Mar 4, 2022 | I | VIOLATION DISMISSED | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Mar 4, 2022 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Jun 30, 2021 | B | VIOLATION DISMISSED | Not available | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION VESTIBULE AT PUBLIC HALL, 1st STORY |
| Jun 30, 2021 | C | VIOLATION DISMISSED | 1F | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS APARTMENT IN THE ENTRANCE LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | B | VIOLATION DISMISSED | 1F | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | B | VIOLATION DISMISSED | 1F | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | B | VIOLATION DISMISSED | 1F | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC WIRE AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | B | NOV SENT OUT | 1F | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER SASH WINDOW COUNTERBALANCES IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | A | VIOLATION DISMISSED | 1F | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE/SINK CABINETS IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | B | VIOLATION DISMISSED | 1F | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER SASH WINDOW COUNTERBALANCES IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | A | VIOLATION DISMISSED | 1F | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WINDOW FRAME IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | C | NOTICE OF ISSUANCE SENT TO TENANT | 1F | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 30, 2021 | C | VIOLATION DISMISSED | 1F | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 15, 2021 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Aug 28, 1998 | C | NOV SENT OUT | Not available | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED. |
| Aug 28, 1998 | C | NOV SENT OUT | 1F | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT KITCHEN AND BATHROOM FIXTURES OF 1 STY APT 1F. LOCATED AT APT 1F |
| Mar 10, 1994 | C | NOV SENT OUT | Not available | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING PADLOCKED SCISSORS GATE AT NORTH FIRE PASSAGE OF BLDG ER1. |
| Jan 20, 1994 | C | NOV SENT OUT | Not available | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR. |
| Jan 20, 1994 | C | NOV SENT OUT | 2R | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT 2 STY APT 2R KITCHEN & BATHROOM. LOCATED AT APT 2R |
| Jun 1, 1987 | B | NOV SENT OUT | Not available | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES 2 STY FRONT APT BATHROOM. |
| Jun 1, 1987 | B | NOV SENT OUT | Not available | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT WALL LIGHT FIXTURES 2 STY FRONT APT CENTER ROOM. |
| Jun 1, 1987 | B | NOV SENT OUT | Not available | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT DOOR 2 STY FRONT APT CENTER ROOM TO NORTH ROOM. |
| Jun 1, 1987 | B | NOV SENT OUT | Not available | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT WINDOW BOTTOM SASH 2 STY FRONT APT CENTER ROOM. |
| Jun 1, 1987 | B | NOV SENT OUT | Not available | D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY GATE & PAD LOCK INSTALLED FIRE PASSAGEWAY FRONT NORTH. |
| Jun 1, 1987 | C | NOV SENT OUT | Not available | D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL. |
| Jun 1, 1987 | B | NOV SENT OUT | Not available | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRING 1 STY PUBLIC HALL CLG. |