| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jun 2, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL |
| Jun 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | A | VIOLATION DISMISSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM . AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. |
| Jun 2, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT FIRE STAIR EXIT DOOR B AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT HOPPER DOOR IN COMPACTOR CLOSET AT PUBLIC HALL, 6th STORY |
| Jun 2, 2023 | B | VIOLATION CLOSED | 6D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 2, 2023 | B | VIOLATION CLOSED | 6D | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 14, 2021 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Oct 23, 2018 | I | VIOLATION DISMISSED | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Aug 22, 2017 | C | VIOLATION CLOSED | 2F | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Aug 22, 2017 | A | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL STOPPER OF THE WASHBASIN IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Aug 22, 2017 | A | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL CEILING LIGHT FIXTURE IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Aug 22, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Aug 22, 2017 | A | VIOLATION CLOSED | 2F | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WALL ERECTED AT SOUTH SUBDIVIDING PRIVATE HALL AND NOTED ROOM IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Aug 22, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK OF THE ENTRY DOOR IN THE ENTRANCE LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jun 2, 2017 | A | VIOLATION CLOSED | 2F | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTITION GREATED FLOOR TO CEILING DIVIDING EAST 2 ROOM. IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jun 2, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECVTRICAL WIRE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jun 2, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING LIGHT FIXTURE IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jun 2, 2017 | B | VIOLATION CLOSED | 2F | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE TUB/SHOWER DIVIDER IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jun 2, 2017 | B | VIOLATION CLOSED | 2F | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE WASH BASIN IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jun 2, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| May 27, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| May 27, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| May 27, 2017 | A | VIOLATION CLOSED | 2F | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION FLOOR TO CEILING PARTITION ERECTED CREATING TWO ROOMS OBSTRACTING LIGHT AND VENTILATION TO SOUTH PART OF THE ROOM IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Apr 20, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Apr 20, 2017 | A | VIOLATION CLOSED | 2F | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION FLOOR TO CEILING PARTITION ERECTED CREATING TWO ROOMS OBSTRACTING LIGHT AND VENTILATION TO SOUTH PART OF THE ROOM IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Apr 20, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Apr 11, 2017 | A | VIOLATION CLOSED | 2F | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTITION ERECTED FROM FLOOR TO CEILING TO CREAT A ROOM IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Apr 5, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SHEETROCK AT NORTH WALL. IN THE FOYER LOCATED AT APT 2F, 1st STORY |
| Apr 5, 2017 | A | VIOLATION CLOSED | 2F | § 27-2076 ADM CODE DISCONTUNUE UNLAWFUL USE OF KITCHEN FOR SLEEPING PURPOSES ... IN THE KITCHEN LOCATED AT APT 2F, 1st STORY |
| Apr 5, 2017 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING. IN THE FOYER LOCATED AT APT 2F, 1st STORY |
| Jan 25, 2017 | A | VIOLATION DISMISSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Feb 19, 2013 | B | VIOLATION CLOSED | 3A | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, APARTMENT AT WEST |
| Feb 19, 2013 | B | VIOLATION CLOSED | 3A | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, APARTMENT AT WEST |
| Feb 5, 2013 | C | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN BATHROOM IN THE PRIVATE HALLWAY LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 5, 2013 | B | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MISSING CERAMIC TILES ON EAST WALL BATHROOM IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 5, 2013 | C | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN BATHROOM IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 5, 2013 | C | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED PLASTER CEILING IN CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jan 29, 2013 | B | VIOLATION CLOSED | 6B | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ... IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jan 29, 2013 | B | VIOLATION CLOSED | 6B | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jul 3, 2002 | B | NOT COMPLIED WITH | 3D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY |
| Jun 1, 2002 | B | NOT COMPLIED WITH | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE HOPPER DOOR AT COMPACTOR CLOSET 3RD STORY MARKED 2ND STORY |
| Jun 1, 2002 | B | VIOLATION CLOSED | 3D | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FAUCET IN MAIN BATHROOM WASH BASIN IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY |
| Jun 1, 2002 | B | VIOLATION CLOSED | 3D | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET MAIN BATHROOM IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY |
| Jun 1, 2002 | B | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLOSET CEILING & WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3D, 3rd STORY |
| Jun 1, 2002 | B | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CLOSET CEILING & WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3D, 3rd STORY |