Queens Astoria (Central)
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 4-00632-0021), so they can include other buildings on the same lot.
123 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| May 6, 2026 | A | NOV SENT OUT | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Nov 21, 2025 | I | INFO NOV SENT OUT | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Sep 30, 2025 | C | NOV SENT OUT | 1R | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE IN THE ENTRANCE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 30, 2025 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE BULKHEAD AT WEST WALL IN THE PUBLIC HALL STAIRS LOCATED AT PUBLIC PARTS, 3rd STORY |
| Jun 11, 2025 | A | NOV SENT OUT | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Mar 13, 2025 | C | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER KEY OPERATOR LOCK INSTALLED AT BUILDING FRONT ENTRANCE DOOR , 1st STORY |
| Mar 8, 2025 | C | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER KEY OPERATOR LOCK INSTALLED AT BUILDING FRONT ENTRANCE DOOR , 1st STORY |
| Mar 8, 2025 | A | NOV SENT OUT | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAILBOX FOR APARTMENT 1F , 1st STORY |
| Dec 4, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH VESTIBULE DOOR AT PUBLIC HALL, 1st STORY |
| Dec 4, 2024 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MAIL BOX DOOR MISSING FOR APARTMENT 1F VESTIBULE AT PUBLIC HALL, 1st STORY |
| Dec 4, 2024 | A | NOV SENT OUT | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Dec 4, 2024 | A | NOV SENT OUT | Not available | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| Dec 4, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUDING BEYOND WINDOW SILL ON 2ND STORY BALCONY BUILDING FRONT AT FIRE ESCAPE |
| Dec 4, 2024 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTHEON PLATES TOP AND BOTTOM ON RISER IN THE 3rd ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 4, 2024 | B | NOV SENT OUT | 1F | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 4, 2024 | B | NOV SENT OUT | 1F | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 4, 2024 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTHEON PLATES TOP AND BOTTOM ON RISER IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 4, 2024 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES ON NORTH, EAST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 4, 2024 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 2, 2024 | I | INFO NOV SENT OUT | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Sep 11, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE AT DOOR LEADING TO EAST YARD AT PUBLIC HALL, 1st STORY |
| Sep 11, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 1st STORY |
| Sep 11, 2024 | B | NOV SENT OUT | 1F | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 11, 2024 | B | NOV SENT OUT | 1F | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 11, 2024 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH AND WEST WALL IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 11, 2024 | B | NOV SENT OUT | 1F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 2, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AND DOOR KNOB ASSEMBLY AT DOOR TO COURT AT PUBLIC HALL, 1st STORY |
| Sep 2, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF STORED PACKAGES AND DEBRIS AT PUBLIC HALL STAIRS, 3rd STORY |
| Sep 2, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND DOOR FRAME BINDING AT EAST DOOR TO ROOF BULKHEAD , 3rd STORY |
| Sep 2, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND DOOR FRAME BINDING AT EAST DOOR TO ROOF BULKHEAD , 3rd STORY |
| Sep 2, 2024 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HASP LATCH WITH EYE ARRANGED TO BE PADLOCKED AT APARTMENT ENTRANCE DOOR IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 2, 2024 | B | NOV SENT OUT | 3F | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 2, 2024 | B | NOV SENT OUT | 3F | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 2, 2024 | B | NOV SENT OUT | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAILBOXES AT NORTH WALL IN VESTIBULE , 1st STORY |
| Apr 12, 2024 | A | NOV SENT OUT | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUDING BEYOND THE WINDOW SILL WEST STACK BUILDING FRONT AT FIRE ESCAPE, 3rd STORY |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS. AND BICYCLE AT PUBLIC HALL, 1st STORY |
| Mar 3, 2024 | A | NOV SENT OUT | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 1st STORY |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER CEILING AT PUBLIC HALL, 1st STORY |
| Mar 3, 2024 | A | NOV SENT OUT | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND NORTH WALL AT PUBLIC HALL, 2nd STORY |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER CEILING AND NORTH WALL AT PUBLIC HALL, 2nd STORY |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 3rd STORY |
| Mar 3, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGEON BULKHEAD DOOR EAST WALL AT PUBLIC HALL, 3rd STORY |
| Mar 3, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE BULKHEAD DOOR WEST WALL AT PUBLIC HALL, 3rd STORY |
| Mar 3, 2024 | A | NOV SENT OUT | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND NORTH WALL AT PUBLIC HALL, 3rd STORY |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER CEILING AND NORTH WALL AT PUBLIC HALL, 3rd STORY |
| Mar 3, 2024 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AND NORTH WALL AT PUBLIC HALL, 3rd STORY |
| Feb 20, 2024 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER AT SECOND STORY BALCONY AT SOUTH BUILDING FRONT AT FIRE ESCAPE |
| Feb 20, 2024 | A | NOV SENT OUT | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 3rd STORY |
| Feb 20, 2024 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 3rd STORY |