Date Class Status Apartment Summary
Jun 14, 2024 B NOV SENT OUT 1 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1, 1st APARTMENT FROM NORTH AT EAST
Jun 14, 2024 A NOV SENT OUT 1 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1, 1st APARTMENT FROM NORTH AT EAST
Jun 14, 2024 C NOV SENT OUT 1 § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT ALL HOT WATER FIXTUES IN ENTIRE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st APARTMENT FROM NORTH AT EAST
Apr 17, 2024 A NOV SENT OUT Not available (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Apr 5, 2024 A NOV SENT OUT Not available § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL
Apr 5, 2024 A NOV SENT OUT Not available § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL
Apr 5, 2024 C NOV SENT OUT Not available § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL
Apr 5, 2024 A NOV SENT OUT Not available § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL
Apr 5, 2024 A NOV SENT OUT Not available § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
Apr 5, 2024 A NOV SENT OUT Not available § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL
Apr 5, 2024 A NOV SENT OUT Not available § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL
Apr 5, 2024 B NOV SENT OUT Not available § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE .. AT FRONT AREAWAY
Apr 5, 2024 B NOV SENT OUT 1 § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTELINE UNDER SINK AT BASEMENT IN THE KITCHEN LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH
Apr 5, 2024 B NOV SENT OUT 1 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL AND ABOVE DOOR FRAME AT BASEMENT IN THE ENTRANCE LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH
Apr 5, 2024 B NOV SENT OUT 1 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL AND ABOVE DOOR FRAME AT BASEMENT IN THE ENTRANCE LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH
Apr 5, 2024 B NOV SENT OUT 1 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT BASEMENT IN THE 4th ROOM FROM NORTH LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH
Apr 5, 2024 C NOV SENT OUT 1 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT BASEMENT IN THE 4th ROOM FROM NORTH LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH
Apr 5, 2024 B NOV SENT OUT 1 § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRIC OUTLETS AT NORTH AND SOUTH WALLS AT BASEMENT IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH
Apr 5, 2024 C NOV SENT OUT Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM
Apr 5, 2024 C NOV SENT OUT 1 § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH
Apr 5, 2024 C NOV SENT OUT 1 § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH
Jan 6, 2024 C VIOLATION CLOSED 1 § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 2nd BSMT-APT FROM SOUTH AT WEST
Jan 6, 2024 C VIOLATION CLOSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM WEST COURT YARD DOOR LEADING TO BOILER ROOM LOCKED
Jan 6, 2024 C VIOLATION CLOSED 1 § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM EAST LOCATED AT APT 1, 2nd APARTMENT FROM SOUTH AT WEST
Jan 2, 2024 C VIOLATION CLOSED 1 § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH
Jan 2, 2024 C VIOLATION CLOSED 1 § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES . IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH
Jan 2, 2024 C NOV SENT OUT 1 § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH , SECTION ''BASEMENT''
Jan 2, 2024 B NOV SENT OUT 1 § 27-2005 HMC: REFIT DOOR , IN THE ENTRANCE LOCATED AT APT 1, 1st APARTMENT FROM WEST AT NORTH , SECTION ''BASEMENT''
Jan 2, 2024 C VIOLATION CLOSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM AT BASEMENT DOOR AT NORTH 1 LOCKED
Jan 2, 2024 C VIOLATION CLOSED 1 § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH
Dec 31, 2023 C VIOLATION CLOSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BASEMENT
Dec 31, 2023 C VIOLATION CLOSED 1 § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Sep 12, 2023 A VIOLATION CLOSED Not available § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL
Sep 12, 2023 A NOV SENT OUT Not available § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL
Sep 12, 2023 C VIOLATION CLOSED Not available § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL
Sep 12, 2023 A VIOLATION CLOSED Not available § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL
Sep 12, 2023 A VIOLATION CLOSED Not available § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
Sep 12, 2023 A NOV SENT OUT Not available § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL
Sep 12, 2023 A VIOLATION CLOSED Not available § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL
Mar 30, 2023 A NOV SENT OUT Not available (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Mar 25, 2023 C VIOLATION CLOSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM FROM FIRST FLOOR TO CELLAR AT BOILER ROOM
Mar 25, 2023 C VIOLATION CLOSED 1 § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Mar 25, 2023 C VIOLATION CLOSED 1 § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING OUTLET SWITCH AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Mar 25, 2023 C VIOLATION CLOSED 1 § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET . IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Mar 13, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION 2 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL (APPROX. 2 SQ. FT.) IN THE FOYER LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 15772852 ISSUED 13-MAR-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
Mar 13, 2023 A NOV SENT OUT 2 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Mar 13, 2023 A NOV SENT OUT 2 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE FOYER LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Mar 13, 2023 A VIOLATION CLOSED 2 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL (APPROX. 2 SQ. FT.) IN THE FOYER LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Mar 13, 2023 B NOV SENT OUT 2 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Mar 13, 2023 B NOV SENT OUT 2 § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FORMICA COUNTERTOP AT BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST