Date Status Type Summary
Jun 23, 2021 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 6, 2020 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK:DURING FACADE/STUCCO REPAIR UNDER JOB440632492,WOOD FRAME EXP 4 WALL ALONG JEFFERSON AVE WAS FOUND TO BE COMPROMISED.BLDG UNSTBL &REQUIRES IMMED SHORNG.OWNR TO IMMED RETN NYSPE &LIC'D CONTRCTR TO INSTL FLR SHORNG @ALL FLRS TO STABLZ BLDG.WRK TO BEGIN 11/7/2020.PE SUPV/DIRCT.PROV MEANS-METD.FILE 2 DAYS.PROV REPTS.ERECT T-BRDFEN.@EXP4
Nov 6, 2020 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED AT EXPOSURE 4 STRUCTURAL WOOD MEMBERS HAVE ROTTED COMPROMISING STABILITY OF BUILDING. FULL VACATE FOR ENTIRE PREMISES.
Oct 28, 2020 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 20, 2020 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTM BLDG SAFE CONDN:EXP1 STORE FRONT FRAMG RACKED TWRDS EXP4 JEFFERSON AVE.EXP1 CORNCE DETERIOR&AT RISK PART COLAP.EXP4 CORNCE@CENTR 3RD ALSO IN DISRPR&AT RISK PART COLPSE.LOCAL BULG&CRCKS@EXP4&LEAN@EXP3/4 CRNER OWNR RETN PE EVAL ENTRE BLDG&SUBMT SIGN&SEAL STABILITY REPT TO FEU BY 9/2/20.PE PREP REPR DWGS.REPR UNDER PRMT BY 10/5/20&CMPLT BY 11/27/20
Aug 6, 2020 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL INSTALL AN APPROX TOTAL OF 44 LINEAR FEET OF SIDEWALK SHED WITH APPROX 24 LINEAR FEET ALONG EXPOSURE 1(WYCKOFF AVENUE)& APPROX.20 LINEAR FEET ALONG EXPOSURE 4 (JEFFERSON AVENUE) IN ORDER TO SAFEGUARD THE PUBLIC AND PROPERTY
Aug 5, 2020 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSP. OBSERVED AT EXPOSURE 4, FACADE BULGING OUTWARD ALONG WITH VERTICAL CRACKS AT CORNER AND WALL. SEPARATION AT TOP BELOW METAL CORNICE OPEN TO ELEMENTS. METAL CORNICE HAS CORRODED AND OPEN TO ELEMENTS. BUILDING IS LEANING ALONG WITH OPENINGS AT EXPOSURE 1 RACKED
Jan 2, 2013 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Mar 1, 2000 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Mar 10, 1981 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL