| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 30, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | DEPT OF RECORDS OBSERVED UNPERMITTED WORK AT CELLAR & 1 FL.W/O PERMITS & IS A POTENTIAL HAZARD TO PUBLIC & PROPERTY REMEDY:RETAIN A NYS LIC P.E. TO PERFORM MONTHLY STABILITY.INSPECTIONS, SUBMIT S/S RPTS BY 7/21 W.PHOTOS,THEN EVERY MONTH UNTIL AUDIT CLEARED |
| Mar 28, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Mar 28, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Mar 16, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | COMMISONER REQUEST FOR CORRECTIVE ACTION (STRUCTURAL STABILITY REPORT) NOTE: OBSERVED AT CELLAR FOUNDATION WALL PARTIAL REMOVAL & REPLACEMENT WITH CMU BLOCK AT EXPOSURE 3 & 4 CORNER. THERE ARE NO PERMITS FOR THIS WORK & STRUCTURAL OF THE ENTIRE BUILDING IN QUESTION |
| Mar 16, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | COMMISSIONER REQUEST FOR CORRECTIVE ACTION STRUCTURAL STABILITY REPORT NOTE INTERIOR RENOVATIONS AT CELLAR AND 1FLOOR LEVEL. OBSERVED FOUNDATION WALL PARTIAL REMOVED AND REPLACE WITH NEW CMU BLOCK AT EXP 3 & 4 CORNER. NO PERMITS FOR THIS WORK. STRUCTURAL STABILITY OF BUILDING IS IN QUESTION |
| Mar 16, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | AS PER THE COMMISSION REQUIRES A STRUCTURE STABILITY REPORT IS REQUIRED. NOTE |