| Date | Status | Type | Summary |
|---|---|---|---|
| Oct 19, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 19, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 19, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 19, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 19, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 19, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 15, 1993 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 14, 1992 | VPW-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 27, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (33)AT 1ST FLOOR ADJUST DOOR & INTERLOCK.(20)HALL INDICATORS.(03) CLEAN CAR TOP,REPLACE MISSING ELECTRIC BOX COVERS ON CAR TOP,REPAIR SIDE WALL AT SIDE EMERGENCY EXIT (CAB WALL).(39)CABLE SLIPPAGE REMOVE FROM SAME |
| Dec 27, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (04)CAB WALLS AT DOOR.(15)SWING NOT TO STICK IN OPEN POSITION.(17 REPLACE WITH CLEAR WINDOW GLASS CAR & LOBBY DOOR GLASS.(20)INDICATORS (35)REPAIR LIGHT SWITCHING & PROIVDE PROPER LIGHTING OVER ALL EQUIPTM IN ROOM.(36)HANDLE & LOCK TO DOOR PROVIDE.(37)ACC RELAY CONTACTS MISSI REPLACE.(74)ADJUST 2ND FLOOR CHECK HOISTWAY DOOR.(03)CLEAN CAR TOP |
| Dec 11, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)PROVIDE 1800 IN CAB CAPACITY PLATE 1800LBS, CLEAN CAR TOP & REPAIR LIGHT.(17)WITH CLEAR WIRE GLASS.(46)CAR TOP SPRINGS REPLACE BROKEN.(52)2ND FLOOR DOOR.(14)PLASTIC SET SCREW |
| Dec 11, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)REPAIR CAB WALL AT AND NEAR SIDE DOOR REAR WALL, PROVIDE IN CAB CAPACITY PLATE 18000LBS. REPAIR CAR TOP LIGHT, CLEAN CAR TOP, REPL SHACKLE SPRING BROKEN CAR TOP.(35)PROVIDE LIGHT SWITCH & PROPER LGHTNG OVER ALL EQUIPTMENT, PROVIDE MISSING ELECTRIC BOX COVERS, CLEAN ROOM (14)PLASTIC & SET SCREW.(17)CAR TO 2 FL. GLASS WITH CLEAR WIRE GLASS |
| Dec 11, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (35)POST ELEV COM. SIGN SECURE ALL ELECTRIC BOX COVERS & LIGHT SWITCH COVER (52)RELINE BRAKE SHOE (03)PROVIDE IN CAR CAPACITY PLATE 1800LBS, CLEAN CAR TOP & REPAIR LIGHT FOR SAME (46)CABLE & SHAKEL SPRINGS BROKEN (50) REMOVE EXCESSIVE NOISE |
| Dec 11, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (14)PLASTIC & SET SCREW.(46)SHACKEL SPRINGS BROKEN REPLACE (74)CLEAN CAR TOP & REPAIR LIGHT.(03) PROVIDE 1800 LBS CAPACITY PLATE IN CAB |
| Dec 11, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (14)PLASTIC & SET SCREW.(46)SHACKEL SPRINGS, BROKEN REPLACE.(74) CLEAN CAR TOP & REPAIR LIGHT.(03)PROVIDE 1800 LBS CAPACITY PLATE IN CAB |
| Jun 22, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 22, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (34) ELIMINATE ERRATIC ACTION |
| Jun 22, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (29) ELIMINATE GRINDING NOISE |
| Jul 11, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (01)PROPERLY FUSE.(32)RENEW BREAK LININGS.(43)EXCESSIVE SIDE PLAY |
| Jul 11, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (32)RENEW BREAK LININGS.(34)CLOSE SPACE AT REAR OF CAR DOOR.(51) REPAIR ALARM BUTTON TO WORK PROPERLY |
| Jul 11, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (10)PROVIDE EMERGENCY EXIT KEYS.(32)RENEW BREAK LININGS.(34)CLOSE SPACE AT REAR OF PANEL.(51)PROVIDE CAPACITY PLATE IN CAR |
| Jul 11, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)RENEW VISION PANEL CAR DOOR.(10)PROVIDE EMERGENCY EXIT KEYS (35)COVER 2ND FLOOR.(43)EXCESSIVE SIDE PLAY.(51)PROVIDE CAPACITY PLATE IN CAR |
| Jul 5, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (43)EXCESSIVE SIDE PLAY.(51)PROVIDE KEY FOR SIDE EXITS ON CAR |