NYC Building Report

Queens South Richmond Hill

124-09 101 Avenue, Queens

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

16 records

Date Status Type Summary
Sep 11, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL UNPERMITTED DEMO OF EXP#3 WALL FOUND ON 5/23/24. LATERAL STABILITY COM PROMISED. SHORING DONE UNDER EMERGENCY WORK; STABILITY UNVERIFIED SINCE 7/2/24. REMEDY: RETAIN PE FOR WEEKLY STABILITY REPORTS. FIRST DUE 9/19/25 TO DOB. SUBMIT EVERY FOLLOWING FRIDAY TO CSE
Feb 12, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL NO REVISED DOCS REC'D BY CSE PER 7/8/24 REQUEST.INITIAL DOCS REC'D 9/18/24, COMMENTS ISSUED 10/18/24.SITE STABILIZED 7/1/24 AFTER UNSAFE DEMO & UNPERMITTED UNDERPINNING COMPROMISED STABILITY. REMEDY: COMPLY W CSE AUDIT. SUBMIT REVISED DOCS PER 10/18/24 MARKUPS BY 2/21/25 TO NYC DOB CONSTRUCTION SAFETY ENGINEERING
May 29, 2024 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL SITE VISIT REVEALD UNPERMITD, UNDESIGND & UNINSPECTD INTERIOR DEMOLITN PROJECT ON 5/23/24,CAUSING LATERAL STABILITY ISSUES &POTENTIAL HAZARDS TO PUBLIC AND PROPERTY. REMEDY: RDP REQUIRD 2 CREATE SITE-SPECIFIC MONITORING PLAN, SUBMIT 2 DEPT,ASSESS IT WEEKLY &PROMPTLY RPT MOVEMENT BY 5/27/24
May 23, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL A SITE VISIT.REVEALD UNPERMITD, UNDESIGND & UNINSPECTD INTERIOR DEMO PROJECT ON 5/23/24, CAUSING LATERAL STABILITY ISSUES & POTENTIAL HZRDS TO PUBLIC AND PROPERTY. REMEDY: NYS REG PE REQUIRD 2 PREPAR STRUCTURL STABILTY RPT, IDENTIFY HAZARDS & ENSURE COMPLIANCE W BLDG CODES, BY 5/27/24
May 23, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL SITE VISIT REVEALD UNPERMITED, UNDESIGND & UNINSPECTED INTERIOR DEMO PROJECT ON 5/23/24, CAUSING LATERAL STABILITY ISSUES&POTENTIAL HAZARDS TO PUBLIC AND PROPERTY. REMEDY: RDP REQUIRD 2 CREATE SITE-SPECIFIC MONITORING PLAN, SUBMIT 2 DEPT,ASSESS IT WEEKLY & PROMPTLY RPT MVEMENT BY 5/27/24
May 23, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL OBSERVED ILLEGAL CONSTRUCTION WAS DONE WITH EXCAVATIONS AND UNDERPINNING. COMPROMISING THE BUILDINGS STRUCTURAL STABILITY. IT IS UNSAFE TO OCCUPY THE BUILDING.
May 23, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNPERMITTED CONSTRUCTION EXCAVATION AND UNDERPINNING WAS DONE AT EXP.# 4 COMPROMISING THE BUILDINGS STABILITY.
Apr 19, 2017 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Apr 5, 2017 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 2, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 2, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Sep 21, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Sep 21, 2016 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 21, 2015 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 21, 2015 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 27, 2008 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL