Date Class Status Apartment Summary
May 11, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UNDER RADIATOR IN THE 1st ROOM FROM EAST LOCATED AT APT 2FL, 2nd STORY
May 11, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UNDER RADIATOR IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2FL, 2nd STORY
May 11, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE FAUCET AT SHOWER BODY IN BATHTUB IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY
May 11, 2011 B NOV SENT OUT Not available SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR AT FRONT ENTRANCE AT PUBLIC HALL, 1st STORY
May 11, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WIRE GLASS TO SKY LIGHT AT CEILING IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
May 11, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE RADIATOR IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
May 11, 2011 B NOV SENT OUT 2FL SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
Apr 15, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR SHUTOFF VALVE(TOTAL TWO) IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
Apr 15, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF LEAK AROUND SKYLITE(STAINS PRESENT) IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
Apr 15, 2011 B NOV SENT OUT 2FL SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
Apr 15, 2011 B NOV SENT OUT Not available SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE HOUSEHOLD AT REAR 10 CU/ YARD, 1st STORY
Apr 15, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AROUND RADIATOR IN THE 1st ROOM FROM EAST LOCATED AT APT 2FL, 2nd STORY
Apr 15, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AROUND RADIATOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 2FL, 2nd STORY
Apr 15, 2011 B NOV SENT OUT 2FL SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
Mar 14, 2011 B NOV SENT OUT 2FL SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
Mar 14, 2011 B NOV SENT OUT Not available SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE BROKEN OUTER GLASS AT LOWER SASH WINDOW AT 2 STORY PUBLIC HALL.
Mar 14, 2011 B NOV SENT OUT Not available SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTERS AT BALUSTRADE 2 STORY BPUBLIC HALL.
Mar 9, 2011 B NOV SENT OUT Not available SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE BUILDING ENTRANCE DOOR AND FRAME , 1st STORY
Mar 9, 2011 C NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR SHUT OFF VALVE IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFL, 1st STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WASH BASIN TO WALL IN THE BATHROOM LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE BATHTUB IN THE BATHROOM LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILINGS AND WALLS INCLUDING CLOSETS IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW SASH IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE APARTMENT ENTRANCE DOOR AND FRAME IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFL, 1st STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS AT SKYLIGHT IN THE KITCHEN LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE TO THE LOWER WINDOW SASH IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFL, 2nd STORY
Mar 9, 2011 B NOV SENT OUT 2NDFL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2NDFL, 2nd STORY
Jan 6, 2011 B NOV SENT OUT Not available SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR AT PUBLIC HALL, 1st STORY
Jan 6, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UNDER RADIATOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2FL, 2nd STORY
Jan 6, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE PILOT LIGHT TO OVEN AT GAS STOVE IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
Jan 6, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UNDER RADIATOR IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2FL, 2nd STORY
Jan 6, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE PILOT LIGHT TO TOP BURNERS AT GAS STOVE IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
Jan 6, 2011 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH OUTER GLASS PANE AT WINDOW IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS LOWER SASH IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR CASING IN THE ENTRANCE LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD VESTIBULE DOOR AT 1ST STORY IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD CASING AT VESTIBULE DOOR AT 1ST STORY IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTER AT BANISTRADE IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
May 16, 2010 B NOV SENT OUT 2FL SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY
Sep 11, 2009 B NOV SENT OUT 2FL SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW PANE GLASS IN THE 1st ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST