| Feb 17, 2016 | B | NOT COMPLIED WITH | 15 | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT STOVE IN THE KITCHENETTE LOCATED AT APT 15, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 17, 2016 | C | VIOLATION CLOSED | 15 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORS IN THE ENTIRE APARTMENT LOCATED AT APT 15, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 17, 2016 | C | VIOLATION CLOSED | 11 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORS IN THE ENTIRE APARTMENT LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 17, 2016 | B | VIOLATION CLOSED | 11 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCES AT UPPER AND LOWER SASHES IN THE 3rd ROOM FROM NORTH LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 17, 2016 | B | VIOLATION CLOSED | 11 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 17, 2016 | B | VIOLATION DISMISSED | 2 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Feb 17, 2016 | B | VIOLATION DISMISSED | 2 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Feb 17, 2016 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO BASEMENT AT BASEMENT, 1st STORY |
| Feb 17, 2016 | B | VIOLATION CLOSED | Not available | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 6th STORY |
| Feb 17, 2016 | A | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 6th STORY |
| Feb 17, 2016 | A | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 2nd STORY |
| Feb 17, 2016 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER AT CEILING AT PUBLIC HALL, 1st STORY |
| Feb 17, 2016 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERODED BRICK AND MORTAR JOINTS AT 6TH STORY DOWN TO 2ND STORY AT WALL AT REAR, NORTH YARD |
| Feb 1, 2016 | I | VIOLATION DISMISSED | Not available | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WILL BECOME LIENS ON THE PROPERTY |
| Oct 15, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK .. |
| Oct 15, 2015 | A | VIOLATION CLOSED | 1920 | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED CEILING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 1920, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 15, 2015 | C | VIOLATION CLOSED | 1920 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 1920, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 6, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ALL SKYLIGHT SAFTY GLASSES AT ROOF |
| Oct 6, 2015 | A | VIOLATION CLOSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Oct 6, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT ALL STORIES THROUGHOUT AT PUBLIC HALL |
| Oct 6, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED BX CABLE AT CEILING AT PUBLIC HALL, 6th STORY |
| Oct 6, 2015 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL AT 4TH & 5TH STY. PUBLIC HALLS & STAIRS |
| Oct 6, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL ON WEST WALL AT 4TH & 5TH STY. PUBLIC HALLS & STAIRS |
| Oct 6, 2015 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING , ALL STORIES THROGHOUT AT PUBLIC HALL |
| Oct 6, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING , ALL STORIES THROGHOUT AT PUBLIC HALL |
| Oct 6, 2015 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL AT BULKHEAD, ROOF. |
| Oct 6, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL ON WEST WALL AT BULKHEAD, ROOF. |
| Oct 6, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT EAST WALL OUT OF PLUMB AT BULKHEAD, ROOF |
| Oct 2, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 6th STORY |
| Oct 2, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT PUBLIC HALL, 2nd STORY |
| Oct 2, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES HANGING AT CEILING AT PUBLIC HALL, 6th STORY |
| Oct 2, 2015 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILING AND WALLS AT ALL STORIES AT PUBLIC HALL |
| Oct 2, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT COLLASPING JOISTS AT CEILING AT PUBLIC HALL, 6th STORY |
| Oct 2, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING OF SOFFIT AT PUBLIC HALL STAIRS, 5th STORY |
| Oct 2, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT 2ND, 3RD, 4TH AND 5TH STORIES AT PUBLIC HALL |
| Oct 2, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOFFIT AT PUBLIC HALL STAIRS, 1st STORY |
| Sep 3, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILINGS AND WALLS AT 6TH STORY PUBLIC HALL . |
| Sep 3, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE STRINGER, HANDRAILING, AND ALL TREADS AT 6TH STORY STAIRCASE LEADING TO ROOF |
| Sep 3, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SKYLIGHT AT ROOF |
| Sep 3, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKWORK AND MOTAR JOINTS AT CHIMNEY ROOF |
| Sep 3, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKWORK AND MOTAR AT WEST PARAPET WALL AT ROOF |
| Sep 3, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKWORK AND MOTAR AT EAST PARAPET WALL AT ROOF |
| Sep 2, 2015 | B | VIOLATION CLOSED | 19 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 19, 5th STORY, APARTMENT AT EAST |
| Sep 2, 2015 | B | VIOLATION CLOSED | 19 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 3rd LIVING ROOM FROM EAST LOCATED AT APT 19, 5th STORY, APARTMENT AT EAST |
| Sep 2, 2015 | B | VIOLATION CLOSED | 19 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 19, 5th STORY, APARTMENT AT EAST |
| Aug 6, 2015 | A | VIOLATION CLOSED | 19 | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 19, 6th STORY, APARTMENT AT SOUTH |
| Aug 6, 2015 | B | VIOLATION CLOSED | 19 | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 19, 6th STORY, APARTMENT AT SOUTH |
| Aug 6, 2015 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT WALLS AND CEILING AT PUBLIC HALL, 6th STORY |
| Aug 6, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 6th STORY |
| Aug 6, 2015 | A | VIOLATION CLOSED | 15 | § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 15, 5th STORY, APARTMENT AT SOUTH |