Date Status Type Summary
Nov 19, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER.SIDEWALK ALONG EXP4 AT WEST 150 ST WAS STRUCT COMPROMISED W/SEVERELY CORRODED STEEL BEAMS,MASONRY ARCHES,M.D&SPALLNG CONCRETE SLAB@VAULT ROOM APPROX 15FT X 20FT.OWNR TO IMMED RTAIN NYSPE& DOB REG GC TO 1.PE TO IMMED SUBMIT MEANS&METHDS TO FEU FOR SHORNG THE VAULT,2.UPON FEU APPROVAL,IMMED SHORE VAULT UNDR FULLTME NYSPE
Nov 19, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.SDWLK VAULT ALONG EXP4 AT W150 ST WAS STRUCT COMPROMISED W/SEVERELY CORRODED STEELBEAMS,MASONRY ARCHES,M.D &SPALLNG CNCRTE SDWLK SLAB@VAULT ROOM APPRX15.OWNR TO RTAIN NYSPE TO EVAL ENT BLDG&FILE RPAIR DWGS W/DOB PERM RPAIR BLDG UNDR PRMT STRTNG BY 1/5/25&CMPLTD/SGND OFF
Nov 19, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL STRUCTURE RENDERED NON-COMPLIANT. CELLAR SIDEWALK VAULT ALONG EXP 4 ST W. 150 ST ,OUTSIDE BOILER ROOM, APPROX 15FT BY 20FT DUE TO STRUCTURALLY COMPROMISED VAULT WITH SEVERE CORRODED STEEL BEAMS AND COMPROMISED METAL DECK AND SIDEWALK SLAB.
Nov 18, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL REQUESTING FOR AN ENGINEER REPORT FOR STRUCTURAL STABILITY OF VAULT CEILING LOCATED AT BASEMENT BOILER ROOM OBSERVED MISSING BRICKS AND DETERIORATING METAL.
Nov 11, 2020 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 11, 2020 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 2, 2019 V*-DOB VIOLATION - DISMISSED BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
May 2, 2019 V*-DOB VIOLATION - DISMISSED BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
May 31, 2018 V-DOB VIOLATION - ACTIVE FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Jan 24, 2018 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 18, 2017 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 2, 2016 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 2, 2016 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 25, 2014 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 31, 2014 V*-DOB VIOLATION - DISMISSED EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
Oct 11, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED THIS PVT REPLACES PVT 488587
Dec 17, 2012 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jan 26, 2011 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Apr 27, 2010 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jan 29, 2009 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 30, 2007 V-DOB VIOLATION - ACTIVE LL1198-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL LL1198-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL
Jan 17, 2007 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 11, 2005 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 8, 2002 V*-DOB VIOLATION - DISMISSED L1198-LOCAL LAW 11/98 - FACADE FACADE REQUIRED L1198-LOCAL LAW 11/98 - FACADE FACADE REQUIRED
Feb 3, 2000 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 1P10422
Feb 10, 1997 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Aug 29, 1995 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 18, 1994 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jan 25, 1994 VP*-VIOLATION UNSERVED ECB- DISMISSED E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 18, 1993 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jul 1, 1992 V*-DOB VIOLATION - DISMISSED LL1080-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL LL1080-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL
Feb 22, 1991 VP-VIOLATION UNSERVED ECB-ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Jul 14, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (75) PROVIDE PUSH PLATE ON HOISTWAY DOORS
Aug 12, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (51) PROPERLY GOV. AFTER CONDUCTING 2YR SAFETY TEST.(52) REPLACE MISSING COVERS IN ELEV. BOXES IN SHAFT .REPAIR OVERHEAD DOOR