Manhattan Washington Heights (South)
667 West 161 Street, Manhattan
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
30 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Aug 18, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jul 21, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Apr 20, 2021 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER DUE TO DEFECTIVE FACADE MASONRY AND WINDOW LINTEL CONDITIONS ON ALL REAR SIDE EXPOSURES AND INTERIOR COURTYARDS REMEDY: IMMED PREVENT PUBLIC ACCESS TO NOTED AFFECTED AREAS MAINTAIN ALL EMERGENCY EGRESS. NOTED MEAAURES TO BE TAKEN UNDER SUPERVISION OF NYS LIC PROF |
| Apr 20, 2021 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | PARTIAL VACATE ORDER. AS OBSERVED ON 4/20/2021 BY FACADE INSPECTOR THERE IS BULGING MASONRY AND STER CRACKS AT EXP 2,3,4, AND EAST AND WEST INTERIOR COURTYARDS. PARTIALLY VACATE EXP 2,3,4 ALLEY WAYS AND EAST AND WEST COURTYARDS. VACATE AREAS ONLY TO BE USED AS EMERGENCY EGRESS. REMEDY: VACATE ALL MENTIONED AREAS |
| Mar 2, 2021 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM THE BUILDING IN A SAFE CONDITION: ON 10/9/2020, 6'X8' SECTION OF TERRACOTTA DECORATIVE LINTEL HAS FALLEN TO SIDEWALK FROM THE 4TH FL AT EXP 1 FACADE OF 667 161ST ST, MN BUILDING. REMEDY: THE BLDG OWNER TO RETAIN A NYS LIC PROFESSIONAL TO EVALUATE THE STABILITY OF FACADES OF EXP 1, EXP 2, AND EXP 3 AND PROVIDE REPORT. OBTAIN PERMIT |
| Feb 3, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 27, 2020 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | PROVIDE APPROXIMATELY 120 LINEAR FEET OF SIDEWALK SHED ALONG EXPOSURE #1(WEST 161ST STREET) TO SAFEGUARD THE PUBLIC AND PROPERTY |
| Oct 13, 2020 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | PROVIDE APPROXIMATELY 160 LINEAR FEET OF SIDEWALK SHED ALONG EXPOSURE #1 (WEST 161ST STREET) TO SAFEGUARD THE PUBLIC AND PROPERTY |
| Oct 9, 2020 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT TIME OF INSPECTION OBSERVED AT 4TH FLOOR APT 4H EXP #1 A SECTION OF TERRACOTTA LINTEL THAT HAS FALLEN TO SIDEWALK |
| Dec 27, 2019 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| May 3, 2019 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Dec 12, 2017 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 10, 2012 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 20, 2011 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Feb 2, 2011 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 5, 2010 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL |
| Apr 20, 2010 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 30, 2008 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 18, 2006 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 8, 2005 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 30, 2004 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 14, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1P10278 |
| Jan 9, 2002 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1P10278 |
| Jan 22, 2001 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1P10278 |
| Nov 23, 1999 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1P10278 |
| Apr 7, 1999 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1P10278 |
| Apr 25, 1991 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | 1 |
| Jun 29, 1990 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | 1 |
| Apr 20, 1990 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 03-CAPACITY PLATE-33-REMOVE LOOSE PLASTER, PROVIDE LIGHT AND PRO- TECTIVE GRILL FOR SKYLIGHT AND REPAIR SHEAVE (CAR)COUNTERWEIGHT) SHAFT AND BEARINGS-40-2 AND 5 YEAR TESTS-53-PROVIDE ELEVATOR COMPANY NAME-37 -AND-25-FILE BN FOR CONTROLLER AND DOOR OPERATOR |
| Nov 14, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (01)SELECTOR CONTINOUSLY GET OUT OF ADJUSTMENT (03)GLASS (24)RESHACKLE (51)REPAIR RELAYS (52)RENEW HALL BUTTONS ENCLOSE WIRES TOP OF CAR |