| Date | Status | Type | Summary |
|---|---|---|---|
| May 6, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE.NOTED AT TIME OF INSPECTION,OBSERVED AT EXPOSURE 1,SPALLING LINTELS.ALSO AT EXPOSURE 2,SPALLING STUCCO,CRACKED AND EXPOSED MASONRY BRICKWORK.REMEDY:REPAIR AND/OR REPLACE |
| Oct 3, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. EXP#4 SPALLING STUCCO @ MULT LOC WITH COLAPSING NEIGHBORING BLDG.#XP#3 MULTIPLE AREAS OF SPALLING STUCCO @ THE 7FL. EXP#2 MULTIPLE CRACKS THROUGHOUT THE FACADE. EXPOSURE #1 DECORATIVE STONE CRACKED. AT 7FL OBSERVED CONICE REMEDY: REPAIR AND/OR REPLACE |
| May 14, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE OBSERVED AT EXP4 EAST ELEV ACTIVELY SPALLING STUCCO/MASONRY FROM 3RD FL TO 6TH FLOOR.SPALLED MASONRY CAN BE SEEN ON FIRE ESCAPE AS WELL AS ADJACENT B UILDING ROOF.ALSO OBSERVED SPALLING STUCCO AT EXP2 W ELEV AS FALLING C EMENTATIONS AROUND 7TH FL WINDOW AT SW CORNER AT EXP1.FIX OR REPLACE |
| Feb 21, 2024 | V-DOB VIOLATION - ACTIVE | FISPHAZ-HAZARDOUS CONDITION (FACADE) FACADE REQUIRED | CYCLE 9C UNSAFE REPORT FILED |
| Jan 10, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:DAMAGED STUCCO W WIND.FRAME AT 6 FLR OF EXP#1,SPALLING @PARAPET COURTYARD.EXP.32,3&EXP CRACK STUCCO AT PARAPET AREA.ROOF AREA CRACKS AT PARAPET WALLS THERE A ARE OTHER COND.@VARIOUS PLACES.REMEDY:MAINTAIN BUILDING REPAIR AND OR REPLACE |
| Nov 22, 2023 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 11, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN EXTERIOR BUILDING-WALLS& APPURT.E:AS NOTED.@TIME OF INSPECT.OBSERV.ON EXPO#1,2,3 &4 SPALLING BRICKS.MASONRY@PARAPET& SEVERAL OTHER LOC. ROOF:CRACKS WERE OBSERVED IN PARAPET MASONRY/STUCCO @ MULTI.LOC.EXPO#1 SOUTH ELEV.SPALLINGMASONRY@7TH FL WINDOW SURROUND MAINT.EXTERIOR BLDG WALLS & APPURT.PROVIDE ADEQ.SAFETY MEASURES |
| Jun 10, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | VACATE ORDER:DUE TO HAZARDOUS CONDITIONS FOUND ON THE BUILDING FACADE AT EXPOSURE 2,3,&4 OWNER IS TO VACATE THE USE OF THE REAR YARD ENTIRE TO ONLY BE USED IN THE EVENT OF AN EMERGENCY DUE TO FIRE ESCAPES.REMER REMEDY:IMMEDIATELY VACATE ACCESS TO REAR YARD EXPOSURES 2,3&4 |
| Jun 10, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER DUE TO LOOSE SPALLING MASONRY ON EXPOSURE 2,3&4 REMEDY:IMMEDIATELY REMOVE ALL LOOSE MASONRY FROM THE FACADE.EVALUATE CONDITION OF FIRE ESCAPE UNDER THE SUPERVISION OF NYS LICENSED PROF ALL LOOSE MATERIAL TO BE REMOVED AND EVALUATION REPORT SUBMITTED TO SSMR@BUILDINGS.NYC.GOV BY 6/21/23 END OF BUSINESS DAY |
| Jun 10, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AS NOTED EXPO#1 SPALLING BRICKS AT PARAPET LEVEL.EXPOSURE 2,3,4 SPALLING STUCCO IN SEVERAL LOCATIONS THROUGH OUT FACADE.ROOF EXPOSURE CRACKS ON PARAPET WALLS ...RUSTED FIRE ESCAPES ON ALL EXPOSURES.REMEDY:MAINTAIN EXTERIOR BUILDING FACADE,REPAIR DAMAGED FACADE |
| Nov 8, 2018 | V-DOB VIOLATION - ACTIVE | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED |
| Oct 30, 2018 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jul 12, 2017 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jul 12, 2017 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Nov 14, 2016 | V*-DOB VIOLATION - DISMISSED | ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST |
| Nov 9, 2015 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 1, 2014 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 5, 2013 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 28, 2011 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 13, 2010 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 1, 2009 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 3, 2008 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Nov 30, 2007 | V-DOB VIOLATION - ACTIVE | LL1198-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL | LL1198-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL |
| Feb 25, 2004 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 21, 2003 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Mar 26, 2002 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 19, 2002 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Nov 8, 2001 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1P10208 |
| Sep 5, 2001 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Mar 8, 2001 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Feb 27, 2001 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Apr 3, 2000 | V*-DOB VIOLATION - DISMISSED | LL10/80-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL | LL10/80-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL |
| Sep 29, 1999 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL |
| Sep 27, 1999 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Mar 16, 1999 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 10, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Sep 1, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Dec 16, 1992 | VP*-VIOLATION UNSERVED ECB- DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jul 2, 1990 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 17-GLASS FRAMES |
| Dec 26, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (03)TOE GUARD (15)BSMT DOOR ROTTED (25)COVER |
| Jan 3, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (51) CLEAN INSTALLATION (52) RESTOR SERVICE TO ALL FLOORS |