Date Status Type Summary
Sep 12, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL RE: FAILURE TO MAINTAIN EXTERIOR BUILDING IN A CODE COMPLIANT MANNER VED MULTIPLE CRACK BRICK FACCES AT VARIOUS LEVELS OF FACADE.SOME SPALL ED.REMEDY:REPAIR AND/OR REPLACE
Sep 12, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN EXTERIOR BUILDING IN A CODE COMPLIANT MANNER.NOTE AT THE TIME OF INSPECTION OBSERVED MULITIPLE CRACK SOME BRICK FACES AT VARIOUS LEVELS OF FACADES SOME SPALLED AND REMOVED SOME STILL CRACKED WILL FALL WHEN FREEZE COMES AROUND. AT EXP # 1,2,3 AND ON THE ROOF REMEDY:REPAIR AND OR REPLACE
Sep 12, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER TO IMMEDIATELY INSTALL SIDEWALK SHED AT HAZARDOUS CONDITIONS OF THE BUILDING MULTIPLE CRACKS BRICK FACE AT EXP #1,2,3 AT PARAPET LEVEL AND OTHER LEVELS OF FACADE. REMEDY: TAKE AND PROVIDE SAFETY MEASURE TO SECURE PUBLIC SAFETY AT EXP #1, PROVIDE SIDEWALK SHED PROTECTION UNDER THE SUPERVISON OF A LICENSED PROFESSIONAL
Sep 12, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER TO IMMEDIATELY INSTALL SIDEWALK SHED AT HAZARDOUS CONDITIONS OF BUILDING. MULDIPLE CRACKED BRICK FACE @ EXP1,2,3 @ PARAPET LEVEL & OTHER LEVELS OF FACADE. REMEDY:TAKE/PROVIDE SAFETY MEASURES TO SECURE PUBLIC SAFETY AT EXP#1,2,3. PROVIDE SIDEWALK SHED PROTECTION UNDER SUPERVISION OF LICENSED PROFESSIONAL
Sep 12, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER TO IMMEDIATELY INSTALL SIDE WALK SHED AT HAZARDOUS CONDITIONS OF THE BLDG MULTIPLE CRACKED BRICK FACE @EXP1,2,3 PARAPET LEVEL AND OTHER LEVEL OF FACADE. REMEDY: TAKE & PROVIDE SAFETY MEASURES TO SECURE PUBLIC SAFETY @ EXP 1,2,3. PROVIDE SIDE WALK SHED PROTECTION UNDER SUPERVISION OF A LICENSED PROFESSIONAL
Sep 2, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER TO IMMEDIATELY INSTALL SIDE WALK SHED AT HAZARDOUS CONDITIONS OF THE BUILDING MULTIPLE CRACKED BRICK FACE AT EXP#1,2,3 AT PARAPET LEVEL AND OTHER LEVELS OF FACADE. REMEDY: TAKE AND PROVIDE SAFETY MEASURES TO SECURE PUBLIC SAFETY AT EXP# 1,2,3 PROVIDE SIDEWALK SHED PROTECTION UNDER SUPERVISION OF LICENSED PROFESS
Jun 23, 2024 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
Apr 22, 2023 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022)
Aug 21, 2022 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021)
Feb 16, 2022 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jun 20, 2021 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020)
Apr 29, 2021 V*-DOB VIOLATION - DISMISSED EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
Jun 29, 2020 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2019)
Mar 18, 2019 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2018
Jan 1, 2012 V*-DOB VIOLATION - DISMISSED BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4