Manhattan East Village
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 1-00405-0015), so they can include other buildings on the same lot.
154 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Nov 22, 2024 | I | VIOLATION DISMISSED | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Oct 15, 2021 | B | VIOLATION CLOSED | 20 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WINDOW STOOL AT WEST WINDOW APPROX 1 SQ FT. IN THE 3rd ROOM FROM NORTH LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 14622045 ISSUED 15-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Oct 15, 2021 | B | VIOLATION DISMISSED | 20 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 15, 2021 | B | VIOLATION DISMISSED | 20 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 15, 2021 | A | VIOLATION CLOSED | 20 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WINDOW STOOL AT WEST WINDOW APPROX 1 SQ FT. IN THE 3rd ROOM FROM NORTH LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 14, 2021 | B | VIOLATION CLOSED | 19 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 14, 2021 | B | VIOLATION CLOSED | 19 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 14, 2021 | A | VIOLATION DISMISSED | 19 | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE MILDEW AT CERAMIC TILES AROUND OF BATHTUB IN THE BATHROOM LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 14, 2021 | B | VIOLATION CLOSED | 19 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AROUND OF STEAM RISER AT CEILING IN THE BATHROOM LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 14, 2021 | A | VIOLATION DISMISSED | 19 | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER IN THE BATHROOM LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 14, 2021 | B | VIOLATION CLOSED | 19 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AROUND OF STEAM RISER IN THE BATHROOM LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 14, 2021 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT ENTRANCE AT BULKHEAD |
| Oct 14, 2021 | B | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER AT ELECTRICAL JUNCTION BOX AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 14, 2021 | B | VIOLATION CLOSED | 20 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 14, 2021 | B | VIOLATION DISMISSED | 20 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2021 | B | VIOLATION CLOSED | 20 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 6 SQ FT AT CEILING IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 14612165 ISSUED 10-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Oct 10, 2021 | B | VIOLATION CLOSED | 20 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2021 | B | VIOLATION CLOSED | 20 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2021 | A | VIOLATION DISMISSED | 20 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2021 | B | VIOLATION CLOSED | 20 | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2021 | A | VIOLATION CLOSED | 20 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 6 SQ FT AT CEILING IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2021 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS AT PUBLIC HALL STAIRS, 4th STORY |
| Oct 10, 2021 | A | VIOLATION CLOSED | Not available | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL STAIRS, 4th STORY |
| Oct 10, 2021 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS AT PUBLIC HALL STAIRS, 5th STORY |
| Oct 10, 2021 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL STAIRS, 5th STORY |
| Oct 5, 2021 | A | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER PLATE OVER OPEN ELECTRIC JUNCTION BOX AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 29, 2021 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT ALL STORIES AT PUBLIC HALL |
| Sep 29, 2021 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ROOF BULKHEAD DOOR AT PUBLIC HALL |
| Sep 29, 2021 | B | VIOLATION CLOSED | Not available | § 53,187,231 M/D LAW & DEPT RULES & REG. PROVIDE MEANS OF EGRESS FROM YARD TO STREET BY FIREPROOF PASSAGEWAY FOR WHICH APPLICATION MUST BE FILED FOR APPROVAL,OR BY UNLOCKED DOOR OR GATE IN FENCE TO ADJOINING PREMISES WITH CONSENT OF ADJACENT OWNER. |
| Aug 14, 2019 | B | VIOLATION CLOSED | 20 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON PLATE AT RISER CEILING IN THE BATHROOM LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 16, 2019 | B | VIOLATION CLOSED | 20 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON PLATE AT CEILING HEAT RISER IN THE BATHROOM LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 14, 2019 | B | VIOLATION DISMISSED | 20 | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| May 14, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 2ND WOOD INTERMEDIATE LANDING FROM BOTTOM UP AT PUBLIC HALL STAIRS, 3rd STORY |
| May 14, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 2ND WOOD INTERMEDIATE LANDING FROM BOTTOM UP AT PUBLIC HALL STAIRS, 4th STORY |
| Mar 5, 2019 | A | VIOLATION DISMISSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL AT PUBLIC HALL, 5th STORY |
| Mar 5, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERAIL AT CEILING AND WEST WALL AT PUBLIC HALL, 5th STORY |
| Mar 5, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 5th STORY |
| Jan 26, 2019 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL AT PUBLIC HALL, 5th STORY |
| Jan 26, 2019 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE NORTH WALL WITH FIRE RETARDANT MATERIALS AT PUBLIC HALL, 5th STORY |
| Jan 26, 2019 | B | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 26, 2019 | B | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 26, 2019 | B | VIOLATION DISMISSED | 20 | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 26, 2019 | B | VIOLATION DISMISSED | 20 | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT BATHTUB WASTE LINE IN THE BATHROOM LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 26, 2019 | A | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 26, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE AT THIRD STORY LANDING AT PUBLIC HALL STAIRS |
| Jan 26, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL AT SECOND STORY LANDING AT PUBLIC HALL STAIRS |
| Nov 7, 2018 | B | VIOLATION DISMISSED | 20 | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 7, 2018 | B | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ESCHUTCHEON PLATES AT HEAT RISER AT CEILING. IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 7, 2018 | B | VIOLATION DISMISSED | 20 | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ESCHUTCHEON PLATES AT HEAT RISER PIPES AT CEILING. IN THE BATHROOM LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 3, 2018 | B | VIOLATION DISMISSED | 20 | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 20, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |