Manhattan East Village
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 1-00443-0052), so they can include other buildings on the same lot.
25 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| May 11, 2026 | C | VIOLATION DISMISSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY |
| Mar 29, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE DEVICE INSTALLED AT VESTIBULE DOOR , 1st STORY |
| Mar 29, 2026 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL AT PUBLIC HALL, 2nd STORY |
| Mar 29, 2026 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 2nd STORY |
| Mar 29, 2026 | C | VIOLATION DISMISSED | 3 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Mar 29, 2026 | C | VIOLATION CLOSED | 3 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDING THE MAXIMUM ALLOWABLE TEMPERATURE OF 130F AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Mar 29, 2026 | C | FALSE CERTIFICATION | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM |
| Mar 29, 2026 | B | VIOLATION CLOSED | 3 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING RADIATOR AIR VALVE IN THE 1st ROOM FROM NORTH LOCATED AT APT 3, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Mar 29, 2026 | C | DEFECT LETTER ISSUED | 3 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Mar 29, 2026 | C | VIOLATION CLOSED | 3 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Aug 27, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES AND ALL BALCONIES, AT BUILDING FRONT AT FIRE ESCAPE |
| Jan 23, 2022 | C | VIOLATION DISMISSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT PUBLIC HALL, 1st STORY |
| Jan 23, 2022 | C | VIOLATION DISMISSED | 19 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Dec 13, 2021 | A | VIOLATION DISMISSED | Not available | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY |
| Dec 13, 2021 | A | VIOLATION DISMISSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. |
| Dec 13, 2021 | A | VIOLATION DISMISSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY |
| Dec 13, 2021 | A | VIOLATION DISMISSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| Dec 13, 2021 | A | VIOLATION DISMISSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. |
| Dec 13, 2021 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CORNICE PARAPET WALL AT ROOF AT BUILDING FRONT |
| Aug 31, 2021 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL TREAD, 10TH FROM BOTTOM AT STAIRS AT BUILDING ENTRANCE |
| Apr 1, 2021 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Sep 6, 2019 | B | VIOLATION DISMISSED | 16 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MORTAR AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 6, 2019 | B | VIOLATION DISMISSED | 16 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 6, 2019 | B | VIOLATION DISMISSED | 16 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 6, 2019 | B | VIOLATION DISMISSED | 16 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |