Date Class Status Apartment Summary
Jul 30, 2019 A VIOLATION CLOSED 2110 § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL .. IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jul 30, 2019 B VIOLATION CLOSED 2110 § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN AND SHOWER IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jul 30, 2019 B VIOLATION CLOSED 2110 § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN AND SHOWER IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jul 30, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jul 29, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jun 18, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jun 18, 2019 C VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jun 18, 2019 C VIOLATION CLOSED 2110 § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASHBASIN IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Jun 18, 2019 C VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 23, 2019 C NOT COMPLIED WITH 2110 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 10 SQUARE FEET AT CEILING. IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 13088678 ISSUED 23-MAY-19 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE ''27-2017.3a(5)(a) or (b).
May 23, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 1st APARTMENT FROM SOUTH AT WEST
May 23, 2019 B VIOLATION CLOSED 2110 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 10 SQUARE FEET AT CEILING. IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 1st APARTMENT FROM SOUTH AT WEST
May 23, 2019 A VIOLATION DISMISSED Not available § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME. AT PUBLIC HALL, 1st STORY
May 23, 2019 A VIOLATION CLOSED Not available § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING SIGN AT PUBLIC HALL, 1st STORY
May 23, 2019 A VIOLATION CLOSED Not available § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
May 23, 2019 C VIOLATION CLOSED Not available § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING SIGN AT PUBLIC HALL, 1st STORY
May 23, 2019 A VIOLATION DISMISSED Not available § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
May 23, 2019 A VIOLATION DISMISSED Not available § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
May 23, 2019 A VIOLATION CLOSED Not available § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
May 23, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2110, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
May 23, 2019 B DEFECT LETTER ISSUED 2110 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 15 SQUARE FEET AT WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2110, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND EAST WALL WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 C VIOLATION CLOSED 2201 § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER GLASS PANE AT EAST WALL WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B VIOLATION CLOSED 2201 § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2201 LOWER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 2201 LOWER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B VIOLATION CLOSED 2201 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE KITCHEN LOCATED AT APT 2201, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B VIOLATION CLOSED 2201 § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE BATHROOM LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B VIOLATION CLOSED 2201 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH AND WEST WALLS IN THE 2nd ROOM FROM EAST LOCATED AT APT 2201 LOWER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B VIOLATION CLOSED 2201 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 2201 LOWER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 LOWER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER FROM APARTMENT ENTRANCE TO WALL PANEL IN KITCHEN LOCATED AT APT 2201, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 A VIOLATION CLOSED 2201 § 27-2005 ADM CODE REFIT DOOR AT NORTH WALL TO TERRACE IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 9, 2019 B NOT COMPLIED WITH 2201 § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED BX ELECTRICAL WIRES AT NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2201 UPPER LEVEL, 22nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Apr 5, 2019 C DEFECT LETTER ISSUED 2110 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL (18 SQ-FT) AND WEST WALL (2 SQ-FT) IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 13001675 ISSUED 05-APR-19 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE ''27-2017.3a(5)(a) or (b).
Apr 5, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH
Apr 5, 2019 B VIOLATION CLOSED 2110 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH
Apr 5, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH
Apr 5, 2019 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, WEST WALL AND CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH
Apr 5, 2019 B VIOLATION CLOSED 2110 § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL AND CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH
Apr 5, 2019 B VIOLATION CLOSED 2110 § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL (18 SQ-FT) AND WEST WALL (2 SQ-FT) IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2110, 21st STORY, 4th APARTMENT FROM WEST AT NORTH
Oct 9, 2018 I VIOLATION DISMISSED Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
May 1, 2018 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL CEILINGS THROUGHT-OUT IN THE ENTIRE APARTMENT LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
May 1, 2018 B VIOLATION CLOSED 2110 § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 2nd BEDROOM FROM NORTH LOCATED AT APT 2110, 21st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Apr 24, 2018 A VIOLATION DISMISSED Not available § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Apr 24, 2018 C VIOLATION CLOSED Not available § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY
Apr 24, 2018 A VIOLATION CLOSED Not available § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING AT PUBLIC HALL, 1st STORY