Date Status Type Summary
Sep 4, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 8, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADD'L INFORMATION REQ:VIO#061319FEU10301FF,OLD STRUCT REPT DTD 3/18/19 REQ EMERG STABL OF FACADE INCLUDING BRACING/STRAPPING/SEALING OF LOOSE CRACK,DETACHED FACADE ROOF/CORNICE/ELEMENTS.OWNR IMMD PROVIDE SIDEWALK CLOSURE T/B/F UND PRMT ALONG FACADE@EAST 9TH ST.& EAST 10TH ST. TO THE SAME SPECIFICATIONS AS IF BC.3306.2.1 WERE APPLICABLE
Aug 8, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADD'L INFORMATION:REQUIRED:VIO #061319FEU10301FF,OLD STRUCTURE REPORT DTD 3/18/19 REQ EMERG STABL OF FACADE INCLUD BRACING/STRAPPING/SEALING OF LOOSE,CRACKED,DETACHED FACADE/ROOF/CORNICE/ELEMENTS.PURSUANT TO 28- 104.7.11.OWN RETAIN PE NYS SURVEYOR TO DEVELOP MONITOR PROGRAM PROVIDE WEEKLY TRANSIT MONITOR REPORTS WITH PE REPORTS
Aug 8, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY:VIO#050119FEU10301FF.IMMED STABL OF UNSAFE STRCTL CONDN@FACADE&STABL WRK WERE TO STRT N/L/THAN 5/28/19&BE CMPL N/L/THAN 6/28/19.NO WRK HAS START AS 8/8/19.REPT DTD 3/18/19 REQ EMERG STABL OF THE FACADE INCLUD BRACE/STRAPPING/SEALING OF LOOSE CRACK,DETACH,FACADE ROOF/CORNICE ELMNTS.COMPLY W COMMISH ORD #050119FEU10301FF CTL#315717
Jun 26, 2019 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jun 13, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADD'L INFO REQD:5ST+C,LNDMRK,REF TO DOB VIO 3/1/19&3/18/19 OLD STRUCT REPORT DEFECTS AT FACADE;DIAGIONAL CRACKS@ N/E+S/E WALLS,MOVEMENT @S/E WALL,FACADE DETACHED&ROOFING MISSING&CRACKS ON CHIMNEY.OWN MUST ENGAGE PE&SURVEYOR TO DEVELOP A MONITOR PROGRAM FOR BUILDING FACADE PROVIDE REPORTS OF FACADE CONDITIONS WITH ENGINEERING RECOMMENDATIONS TO DOB
May 16, 2019 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
May 1, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:5ST+C LNDMRK.DOB# 315701 & 3/18/19 OLD STRUC REPRT REQ EMRG STABIL OF FAC.DEFECTS:DIAG CRKS,MOVMT,ELEMENTS DETACH, STN & RFG MISSING,CRKS ON CHIMNEY.EMRGWRK:OWN IMMED ENG PE & DOB LIC CONTR TO STABILIZ UNSAFE CONDS @FAC PURSUANT TO 28-105.4.1 WORK CONT SUPERVISED BY PE.STRT WRK N/L/THAN 5/28/19 &COMPL 6/28/19. FILE FOR PERMIT 2 DAYS AFTER START
Apr 5, 2019 V-DOB VIOLATION - ACTIVE EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST
Mar 4, 2019 V*-DOB VIOLATION - DISMISSED LANDMK-LANDMARK NONE LANDMK-LANDMARK NONE
Mar 1, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN. BUILDING IS A 5 STORY + CELLAR, "H" SHAPE "SNYDER TYPE", 150' X 183' +/- LANDMARK BUILDING ON THRU LOT 150' X 185' +/- IT WAS A SCHOOL (OLD PS 64) BUILT AROUND 1902 AND WAS UNOCCUPIED FOR 18 YEARS WITHOUT MAINTENANCE. DISCOVERED DURING INSPECTION THAT THE BU ILDING WAS STRIPPED OF ARCHITECTURAL FINISHES, FIRE PROOFING AND ON EA
Mar 1, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN. BUILDING IS A 5 STORY + C, "H" SHAPE "SNYDER TYPE ", 150' X 183' +/- LANDMARK BUILDING ON THIS LOT 105' X 185' +/-. IT W AS A SCHOOL (OLD PS 64) BUILT AROUND 1902 AND WAS UNOCCUPIED FOR 18YRS WITHOUT MAINTENANCE. AT A MIN., CRACKS OBSERVED AT NE, NW AND SE CORN ER OF BUILDING HAVE STARTED TO BE DETACHED FROM BACK UP WALLS, GAS 1"-
Feb 16, 2019 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Feb 6, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:5ST+C BLDG ON THRU LOT IT WAS A SCHOOL PS 64 BLDG UNOCCUP 18 YRS W/O MAINTENANCE DISCOVERED DURING INSP 2/6/19 THE BLDG WAS STRIPPED OF ARCH.FINISHES,FIRE PROOF&ELECT ON 2-5FLS&FILLER BEAMS EXPOSED CRACKS OBSERVED ON E-W WALLS FROM 3 ROOF OWN HIRE PE EVAL COND OF INTR OF THE BLDG PROV RPT/W FINDING,RECOMMEND&LIST OF HAZARDS N/L/THAN 2/25/19
Feb 6, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:5ST+C ON THRU LOT IT WAS A SCHOOL (PS64) BLDG UNOCCUPIED 18 YRS W/O MAINTENANCE@A MIN CRACKS OBSERVED ON E-W WALLS NEAR N-S WALLS FROM 3FL TO ROOF FLS.ORNAMENTAL STONE FACADE STARTED TO DETACH FROM BACK UP WALLS.CHIMNEY CRACKED@ROOF OWN HIRE PE EVAL CONDITIONS OF FACADE PRVD RPT W/FINDINGS,RECOMMENDATIONS&LIST OF HAZARDS NO LATER THAN 2/25/19
Feb 2, 2018 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Nov 2, 2017 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Aug 2, 2017 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
May 2, 2017 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Feb 3, 2017 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Nov 3, 2016 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Aug 3, 2016 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Jun 2, 2016 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Feb 2, 2016 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Nov 2, 2015 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Aug 6, 2015 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL BORO-COMM HAS ISSUED A LETTER OF INTENT TO REVOKE PERMIT 121329801 AS ON SEPT 22/2014 REMEDY: STOP ALL WORK
Aug 2, 2015 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
May 2, 2015 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Sep 23, 2014 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL BORO-COMM
Jun 6, 2014 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Jan 15, 2014 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jun 3, 2013 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Mar 1, 2013 V*-DOB VIOLATION - DISMISSED EGNCY-EMERGENCY NONE EGNCY-EMERGENCY NONE
May 3, 2012 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Jan 1, 2012 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Nov 30, 2011 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 15, 2010 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 8, 2010 V-DOB VIOLATION - ACTIVE VCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED VCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED
Nov 23, 2009 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL STOP ALL WORK FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY ATTACHED B Y CONSTRUCTION OPERATIONS AT TIMEOF INSPECTION I DID OBSERVE GAS CYLIN DER NOT STORED PRPERTY SEVERAL FIRE EXTINGUISHERS NOT CHARGED REMEDY: STOP ALL WORK SAFEGUARD PUBLIC AND PROPERTY
Sep 26, 2008 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Aug 11, 2008 VW*-VIOLATION - WORK W/O PERMIT DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL