Manhattan Midtown South-Flatiron-Union Square
DOB complaints
Department of Buildings complaints attached to this BIN. Category and disposition text come from DOB’s published code lists; some newer codes have no published description yet.
9 records
-
Aug 27, 2026
CLOSED
Building Shaking/Vibrating/Struct Stability Affected (30)
Ecb Violation Served (A8)
- Complaint #
- 1734893
- DOB unit
- ERT
- Inspected
- Aug 28, 2026
- Disposition date
- Aug 28, 2026
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Jul 17, 2026
CLOSED
7J
Ecb Violation Served (A8)
- Complaint #
- 1731077
- DOB unit
- RTEU
- Inspected
- Jul 17, 2026
- Disposition date
- Jul 17, 2026
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Feb 9, 2026
CLOSED
Boiler - Defective / Inoperative / No Permit (58)
No Violation Warranted For Complaint At Time Of Inspection (I2)
- Complaint #
- 1716507
- DOB unit
- BOILR
- Inspected
- Mar 24, 2026
- Disposition date
- Mar 24, 2026
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Apr 8, 2024
CLOSED
Egress - Locked/Blocked/Improper/No Secondary Means (37)
No Violation Warranted For Complaint At Time Of Inspection (I2)
- Complaint #
- 1664760
- DOB unit
- ERT
- Inspected
- Apr 9, 2024
- Disposition date
- Apr 9, 2024
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Aug 24, 2018
CLOSED
Illegal Hotel Rooms In Residential Buildings (4A)
Inspector Unable To Gain Access - 2nd Attempt (C2)
- Complaint #
- 1487961
- DOB unit
- SPOPS
- Inspected
- Feb 15, 2019
- Disposition date
- Feb 15, 2019
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Jul 6, 2016
CLOSED
Building Shaking/Vibrating/Struct Stability Affected (30)
No Violation Warranted For Complaint At Time Of Inspection (I2)
- Complaint #
- 1427820
- DOB unit
- ERT
- Inspected
- Jul 7, 2016
- Disposition date
- Jul 7, 2016
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Jul 1, 2016
CLOSED
Building Shaking/Vibrating/Struct Stability Affected (30)
No Violation Warranted For Complaint At Time Of Inspection (I2)
- Complaint #
- 1427617
- DOB unit
- ERT
- Inspected
- Jul 4, 2016
- Disposition date
- Jul 5, 2016
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Jun 17, 2016
CLOSED
Wall/Retaining Wall - Bulging/Cracked (54)
Complaint Referred To Housing Preservation And Development (Hpd) (F8)
- Complaint #
- 1426502
- DOB unit
- MAN.
- Inspected
- Jul 5, 2016
- Disposition date
- Jul 5, 2016
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5
-
Nov 8, 2004
CLOSED
Debris/Building -Falling Or In Danger Of Falling (10)
No Violation Warranted For Complaint At Time Of Inspection (I2)
- Complaint #
- 1131691
- DOB unit
- MAN.
- Inspected
- Nov 8, 2004
- Disposition date
- Nov 8, 2004
- Address on complaint
- 33 West 16 Street
- Community board
- Manhattan CB 5