| Sep 11, 2024 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTE:OBSERVED @ EXP #1 NORTH ELEVATION DETERIORATING MASONRY FROM FL 1-4 WHICH INCLUDES STEP CRACKS;DAMAGED MORTAR JOINTS; MISSING/OPEN SECTIONS OF BRICKS; SPALLED BRICKS/STONE. REMEDY: FIX AND/OR REPLACE |
| Feb 6, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES NOTE:OBSERVED DAMAGED BRICKAND MORTAR JOINTS AT THE SOUTH WEST CORNER OF EXPOSURE#1 REMEDY:MAINTAIN BUILDING EXTERIOR WALLS,FACADE AND APPURTENANCES |
| Jan 11, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM BLDG IN A CODE COMPLIANT MANNER. OBSEVED DAMAGED BRICK AND MORTAR JOINTS ON EXP1 SOUTH ELEVATION. REMEDY: COMPLY WITH CODE |
| Oct 18, 2022 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. OBSERVED DAMAGED BRICKS ON FLOORS 1,2 AND 3 ON EXPOSURE 2 WEST ELEVATION REMEDY: REPAIR OR REPLACE BRICKS THAT ARE DAMAGED ON ALL VISIBLE EXPOSURES |
| Jun 1, 2022 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM BUILDING IN CODE COMPLIANT MANNER. ON EXP2 WEST ELEVATION OBSERV DAMAGED BRICKS AT FLOORS 1,2, AND 3, SPALLING STUCCO ON PARAPET ON EXP1 SOUTH ELEVATION. REMEDY: REPAIR OR REPLACE DAMAGED BRICKS/MASONRY ON ALL VISIBLE EXPOSURES |
| Jul 14, 2021 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM EXTERIOR BUILDING FACADE AND APPURTENANCES. AT TIME OF INSP OBSERVED DEFECTIVE FACADE AT EXP 1 SOUTH ELEVATION. DEFECTIVE MASONRY WORK SUCH AS: LOOSE BRICK, CHIPPED CONCRETE, CRACK, SPALLED BRICKS REMEDY: MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. TAKE SAFETY MEASURES AND REPAIR DAMAGED FACADE AS PER 1RCNY 103-04 |
| Jun 5, 2021 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM BUILDING EXTERIOR WALL/FACADE AND APPURTENANCES. AT TIME OF INSP OBSERVED MISSING PARAPET WITH LOOSE BRICK ON EDGE AND STEP CRACKING WINDOW COVER WITH PLY AND ONE MISSING LIVING OPEN AREA REMEDY: MAINTAIN BUILDING EXTERIOR WALLS/FACADE AND APPURTENANCES REPAIR DEFECT AS PER 1 RCNY 103-04 |
| Nov 8, 2019 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT |
| Apr 6, 2018 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT |
| May 12, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FM.OWNERS RESPONSIBILITY TO KEEP BLDG IN A SAFE CONDITION @ ALL TIMES DEFECTS INCLUDE(1)ROOF STRUCTURE IS ALMOST ENTIRELY MISSING(2)NORTH & EAST WALLS @ REAR OF BLDG ARE POTENTIALLY UNSTABLE(3)FRONT FACADE BRICK WALL HAS GAPS&CRACKS@SOUTHEAST CORNER.REMEDY:OWNER TO RETAIN NYSPE TO EVAL BLDG.OBTAIN BEGIN WORK NO LATER THAN JUNE 17, 2016 |
| May 12, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FM.OWNERS RESPONSIBILITY TO KEEP BLDG IN A SAFE CONDITION AT ALL TIMES DEFECTS INCLUDE:(1)ROOF PARTIALLY COLLAPSED(2)EAST BRICK WALL MISSING @ UPPER FLRS AND BRICK CHIMNEY FLUES ARE UNSUPPORTED(3)CELLAR TIMBER GILDER&POSTS ARE DETERIORATED.REMEDY:OWNER TO RETAIN NYSPE TO EVALUATE BLDG.OBTAIN PERMIT NO LTR THAN JUNE 3, 2016 BEGIN WRK NO LTR 06/17/16 |
| Mar 23, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Mar 23, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Mar 23, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Mar 19, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BORO-COMM |
| Mar 18, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BORO-COMM |
| Jan 28, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BORO-COMM |
| Mar 19, 2003 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 16, 1999 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 4, 1998 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 13, 1992 | VP*-VIOLATION UNSERVED ECB- DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |