NYC Building Report

Manhattan East Village

29 St Marks Place, Manhattan

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

24 records

Date Status Type Summary
Jul 29, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNPERMTD PARTL DEMO & ALT WRK @ 4STRY MIXD-USE BLDG, INTEROR WALLS REMV'D & UNDOCUMTD SHORING IN UNIT 2B, CRACKS & SAGGING IN UNIT3B, ROOF POTENTIALLY COMPROMISED. REMEDY: FAIL 2 COMPLY W ORDER 2 COMMENCE STABILIZATN WRK UNDR PERMIT COMMENCE TEMPORARY STABILIZATION WRK UNDER PERMIT BY 7/29/25
Jul 17, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNPERM'D PARTL DEMO & ALT WRK @ 4STRY MIXD-USE BLDG, INTERIOR WALLS REMV'D & UNDOCUMTD SHORING IN UNIT 2B, CRACKS & SAGGING IN UNIT 3B, ROOF POTENTIALLY COMPROMISED. REMEDY: FAIL TO COMPLY W.DOB VIO# 071725CE10301JT. COMPLY W CODE, COMMENCE TEMPORARY STABILIZATION WORK UNDR PERMT BY 7/29/25
Jul 17, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNPERMTD PARTL DEMO & ALT WRK @ 4STRY MIXD-USE BLDG, INTERIOR WALLS RE MOVED & UNDOCUMENTED SHORING IN UNIT 2B, CRACKS & SAGGING IN UNIT 3B, ROOF POTENTIALLY COMPROMISED. REMEDY: COMPLY W CODE. COMMENCE TEMPOR ARY STABILIZATION WORK UNDER PERMIT BY 7/25/25
Jul 17, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNPERMTD PARTL DEMO & ALT WRK @ 4STRY MIXD-USE BLDG, INTERIOR WALLS REMV'D & UNDOCUMTD SHORING IN UNIT 2B, CRACKS & SAGGING IN UNIT 3B, ROOF POTENTIALLY COMPROMISED. REMEDY: COMPLY W CODE. PERFORM ENGINEERNG INVESTGTN.ON 3 FL & ROOF SHOWING CALCS,COMPLY WITH BC1604.2. SUBMIT CALCS BY 7/29/25
Dec 23, 2024 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 23, 2024 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 11, 2024 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 16, 2024 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL OBSERVED STRUCTURAL WORK IN PROGRESS BETWEEN FLOORS W/ TEMPORARY MAKESHIFT SHORING ON OCCUPIED BUILDING TO SECURE/SUPPORT FLOORS.BETWEEN 3RD&4TH FLOORS @ APT#3B OBSERVED SEVERE SLOPPING SAGGING AT LIVING ROOM, HALLWAYS &SEVERE CRACKS AT CEILING, NO SPECIAL INSPECTIONS TR1 FILLED. STOP ALL WORK AT FLOORS 2 & 3.
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Nov 8, 2019 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Dec 2, 2010 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 2, 2010 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 2, 2010 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jan 3, 2008 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 19, 2003 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Feb 27, 2001 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Feb 7, 2000 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 16, 1999 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Aug 29, 1995 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 18, 1993 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED