| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jan 14, 2026 | A | NOV SENT OUT | 5 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE BATHROOM LOCATED AT APT 5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 14, 2026 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 5 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 14, 2026 | B | VIOLATION DISMISSED | 5 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 14, 2026 | B | VIOLATION DISMISSED | 5 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 14, 2026 | C | VIOLATION CLOSED | 5 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET IN THE ENTRANCE LOCATED AT APT 5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jan 14, 2026 | C | VIOLATION CLOSED | 16 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 16, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jan 14, 2026 | B | NOV SENT OUT | 16 | § 27-2005 HMC: REFIT THE DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT 16, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Nov 29, 2025 | B | NOV SENT OUT | 12 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK MECHANISM AT DOOR IN THE ENTRANCE LOCATED AT APT 12, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Nov 29, 2025 | B | NOV SENT OUT | 12 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT 1ST LOWER SASH WINDOW 1ST FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 12, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Nov 29, 2025 | B | NOV SENT OUT | 12 | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 12, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Nov 17, 2025 | I | VIOLATION DISMISSED | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Nov 3, 2025 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 6 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT NORTH WALL, SOUTH WALL AND CEILING IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18342349 ISSUED 03-NOV-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Nov 3, 2025 | A | NOV SENT OUT | 6 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST, THE BATHROOM , THE KITCHEN LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Nov 3, 2025 | C | NOV SENT OUT | 6 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Nov 3, 2025 | A | NOV SENT OUT | 6 | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Nov 3, 2025 | C | NOTICE OF ISSUANCE SENT TO TENANT | 6 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Nov 3, 2025 | A | NOV SENT OUT | 6 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE FOYER LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Nov 3, 2025 | A | VIOLATION CLOSED | 6 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT NORTH WALL, SOUTH WALL AND CEILING IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Oct 12, 2025 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT VESTIBULE DOOR , 1st STORY |
| Oct 3, 2025 | C | VIOLATION DISMISSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WIRE GLASS AT VESIBLUE DOOR , 1st STORY |
| Oct 3, 2025 | A | NOV SENT OUT | Not available | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR THOUGHOUT AT BASEMENT |
| Oct 3, 2025 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGE AT BOILER ROOM |
| Oct 3, 2025 | C | NOV SENT OUT | 2 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGE IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 15, 2025 | I | INFO NOV SENT OUT | Not available | § 27-2091(C) ADM CODE THE PROPERTY HAS BEEN ISSUED AN ORDER TO IDENTIFY AND ADDRESS UNDERLYING CONDITIONS AND VIOLATIONS RELATED TO THE ORDER. FAILURE TO COMPLY MAY RESULT IN EXTENSIVE REPAIR WORK TO CORRECT UNDERLYING CONDITIONS AND RELATED VIOLATIONS BY HPD. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WILL BECOME TAX LIENS ON THE PROPERTY |
| Aug 22, 2025 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 9 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN SQUARE FEET AT WEST WALL IN THE BATHROOM LOCATED AT APT 9, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18181101 ISSUED 22-AUG-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Aug 22, 2025 | A | NOV SENT OUT | 9 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 9, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Aug 22, 2025 | A | VIOLATION CLOSED | 9 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN SQUARE FEET AT WEST WALL IN THE BATHROOM LOCATED AT APT 9, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Aug 22, 2025 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM |
| Aug 22, 2025 | C | VIOLATION DISMISSED | 9 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 9, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Aug 21, 2025 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASMENT AT BOILER ROOM |
| Aug 21, 2025 | C | VIOLATION DISMISSED | 12 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 12, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 29, 2025 | B | NOT COMPLIED WITH | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 3/8 BOLT AT SHOE DROP LADDER AT STACK AT BUILDING FRONT AT FIRE ESCAPE |
| Jul 16, 2025 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 5th STORY |
| Jul 16, 2025 | B | NOV SENT OUT | 12A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH 2 WINDOW CASING HEADER IN THE 4th ROOM FROM NORTH LOCATED AT APT 12A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 16, 2025 | B | VIOLATION DISMISSED | 12A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT THE WINDOW CASING HEADER,WEST AND EAST WALLS IN THE BATHROOM LOCATED AT APT 12A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 2, 2025 | B | NOV SENT OUT | 4 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE FOYER LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | NOV SENT OUT | 4 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE FOYER LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | NOV SENT OUT | 4 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | NOV SENT OUT | 4 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | VIOLATION DISMISSED | 4 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | VIOLATION DISMISSED | 4 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | C | NOTICE OF ISSUANCE SENT TO TENANT | 4 | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT RATS IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | VIOLATION DISMISSED | 16 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | B | VIOLATION DISMISSED | 16 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jul 2, 2025 | C | NOTICE OF ISSUANCE SENT TO TENANT | 16 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Jun 27, 2025 | B | NOT COMPLIED WITH | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT VESTIBULE HALLWAY , 1st STORY |
| Jun 27, 2025 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 4th STORY |
| Jun 27, 2025 | A | VIOLATION DISMISSED | 12A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 12A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 14, 2025 | A | NOT COMPLIED WITH | Not available | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT BUILDING FRONT AT FIRE ESCAPE |
| Jun 14, 2025 | B | NOT COMPLIED WITH | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD STORAGE AT BALCONY AT NORTH FRONT BUILDING STACK AT FIRE ESCAPE, 5th STORY |