107 records

Date Class Status Apartment Summary
Aug 15, 2026 C NOV CERTIFIED LATE Not available § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 13TH METAL TREAD FROM BOTTOM UP OF 2ND STORY BALCONY AT EAST EXTERIOR AT FIRE ESCAPE
Jul 27, 2026 C VIOLATION CLOSED 4W § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Jul 27, 2026 C VIOLATION DISMISSED 4W § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Jul 27, 2026 B CIV14 MAILED 3C § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jul 27, 2026 B CIV14 MAILED 3C § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jul 27, 2026 C VIOLATION DISMISSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM
Jul 27, 2026 C VIOLATION DISMISSED 3C § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Apr 15, 2025 A VIOLATION DISMISSED 4E § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH WINDOW AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4E, 4th STORY, APARTMENT AT EAST
Apr 15, 2025 A VIOLATION DISMISSED 4E § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH WINDOW AT NORTH IN THE KITCHEN LOCATED AT APT 4E, 4th STORY, APARTMENT AT EAST
Dec 29, 2024 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DUE TO THE LATCH SET AND HINGES AT THE VESTIBULE , 1st STORY
Dec 2, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE MISSING DOOR AT PUBLIC HALL, 1st STORY
Dec 2, 2023 C VIOLATION DISMISSED 2W § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING 130 DEGREES FAHRENHEIT AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2W, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Dec 2, 2023 C VIOLATION DISMISSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
Dec 2, 2023 C VIOLATION DISMISSED 2W § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2W, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Nov 27, 2023 C VIOLATION DISMISSED 3W § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
Nov 27, 2023 C VIOLATION CLOSED 3W § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
Feb 27, 2023 B VIOLATION DISMISSED 5W § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Feb 27, 2023 B VIOLATION DISMISSED 5W § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Feb 27, 2023 C VIOLATION DISMISSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
Feb 27, 2023 C VIOLATION DISMISSED 5W § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Feb 27, 2023 C VIOLATION DISMISSED 5W § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Jan 23, 2023 B VIOLATION DISMISSED 3C § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jan 23, 2023 B VIOLATION DISMISSED 3C § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jan 23, 2023 C VIOLATION DISMISSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED ROOM AT BOILER ROOM
Jan 23, 2023 B VIOLATION DISMISSED 3C § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jan 23, 2023 B VIOLATION DISMISSED 3C § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER WINDOW SASH AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jan 23, 2023 C VIOLATION DISMISSED 3C § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jan 23, 2023 C VIOLATION DISMISSED 3C § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Nov 23, 2022 C VIOLATION DISMISSED Not available § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SHOPPING CART UNDER DROP LADDER AT FIRE ESCAPE
Mar 24, 2022 C VIOLATION DISMISSED Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BASEMENT DOOR LOCKED AT BOILER ROOM
Mar 24, 2022 C VIOLATION DISMISSED 2C § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Apr 1, 2021 A VIOLATION DISMISSED Not available (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Aug 13, 2019 A VIOLATION DISMISSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 3rd STORY
Aug 13, 2019 B VIOLATION DISMISSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL AT INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 3rd STORY
Aug 13, 2019 A VIOLATION DISMISSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 4th STORY
Aug 13, 2019 B VIOLATION DISMISSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL AT INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 4th STORY
Aug 6, 2019 A VIOLATION DISMISSED Not available § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD., 1st STORY
Aug 6, 2019 B VIOLATION DISMISSED Not available § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIAL STORED AT PUBLIC HALL, 1st STORY
Aug 6, 2019 A VIOLATION DISMISSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH WALL AT PUBLIC HALL STAIRS, 5th STORY
Aug 6, 2019 B VIOLATION DISMISSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL AT PUBLIC HALL STAIRS, 5th STORY
Aug 6, 2019 B VIOLATION DISMISSED Not available § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL AT PUBLIC HALL STAIRS, 5th STORY
Aug 6, 2019 C VIOLATION CLOSED Not available § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT SOUTH WALL AT PUBLIC HALL, 4th STORY
Aug 6, 2019 C VIOLATION CLOSED Not available § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT SOUTH WALL AT PUBLIC HALL, 2nd STORY
Aug 6, 2019 A VIOLATION DISMISSED Not available § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Jan 17, 2019 C VIOLATION CLOSED 4C § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF SLIDE BOLT INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Jun 24, 2018 B VIOLATION CLOSED 5E § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Jun 24, 2018 B VIOLATION CLOSED 5E § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Jun 24, 2018 B VIOLATION CLOSED Not available § 27-2005 ADM CODE PROVIDE WIRE PROTECTIVE SCREEN BELOW SKYLIGHT, AT BULKHEAD TO ROOF , 5th STORY
Jun 24, 2018 A VIOLATION CLOSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL , 5th STORY
Jun 24, 2018 B VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING PLASTER, NORTH WALL, IN THE BULKHEAD TO ROOF. , 5th STORY