Jun 1, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE.AS NOTED AT EXP2,OBSERVED VERTICAL BRIC K STEP CRACK,ALSO VERTICAL BRICK STEP CRACK AT EXP4.OBSERVED AT ROOF E LEVATION COUNTLESS HAIRLINE CRACKS ON PARAPET.CRACKING OBSERVED THROUG HOUT BULKHEAD.REMEDY:REPAIR AND/OR REPLACE
Jul 8, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT THE TIME OF INSPECTION,I OBSERVED ON EXP 2 SOUTH ELEV:ERODING BRICKS,SPALL ING MORTAR BENEATH COPING TILES AT PARAPET.MULTIPLE CRACKED SILLS ON S EVERAL FLOORS,CRACKS IN BRICK WORK AT MULTIPLE SPANDRELS.EXP3&4 WEST & NORTH ELEV:STEP CRACKS IN BRICK WORK.REMEDY:REPAIR AND/OR REPLACE
Sep 27, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION OBSERVED STEP CRACK AT PARAPET WALL OF EXPOSURE 4 BOWING LINTELS AT EXPOSURE #4 MULTIPLE LEVELS AND SPALLING COATING AT EXPOSURE #2. DAMAGED MISSING/CRACKED COPING STONES. REMEDY: REPAIR AND/OR REPLACE
May 17, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED STEP CRACKING, DAMAGED AND MISSING MORTAR JOINTS ON EXPOSURE 4 NORTH ELEVATION. REMEDY: REPAIR AND OR REPLACE
Jan 10, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AT THE TIME OF INSPECTION OBSERVED ON EXPOSURE 2 MISSING MOTAR JOINTS AT EXPOSURE 3 STEP CRACK WERE OBSERVED IN MULTIPLE LOCATION AND SPALLING MOTAR JOI JOINTS&@ EXPO# 4 OBSERV.CRACK WIND. SILL & CRACK BRICK&SPALLING MORTAR REMEDY:MAINT.BLDG IN A CODE COMPLIANT MANNER MAKE NECESSARY REPAIRS
Sep 6, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AT THE TIME OF INSPECTION OBSERVED ON EXPO#4 NORTH ELEVATION:SAGGING CORRODING METAL LINTELS ON SEVERAL FLOORS;BULGING & DISLODGE BRICKS AT CORRODING METAL LINTEL.ON SEVERAL FLOORS. REMEDY MAINTAIN BUILDING IN A CODE COMPIANT MANNER.MAKE NECESSARY REPAIRS TO FACADE APPURTENANCES
Feb 14, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED DAMAGED/OPEN MORTAR AT EXP1 1ST FLOOR, EXP4 NORTH ELEV DAMAGED/ERRODED MORTAR JOINTS AND BOWED WINDOW LINTEL. REMEDY: REPAIR AND OR REPLACE
Nov 16, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN A CODE COMPLIAN MANNER. OBSERVED DAMAGED/ERRODED MORTAR JOINTS AND INADEQUATE REPAIRS ON EXP4 NORTH ELEV. REMEDY: REPAIR AND/ OR PLACE
Aug 2, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK IRDER DUE TO IMMINENT HAZARDOUS CONDITIONS ON FACADE AT EXPOSURE 1 EAST ELEVATION OVER MAIN ENTRANCE WALK WAY AND SIDEWALK OBSERVED CRACKS, AND STEP CRACKS, BULGING, DISLODGE BRICKS ON SEVERAL FLOORS AT CORRODED SAGGING LINTELS. REMEDY: IMMED REPAIR AND OR REPLACE ALL DAMAGED FACADE BRICKS AND METAL LINTELS
Aug 2, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED ON EXP1 EAST ELEV: DAMAGED, CRACKED MORTAR JOINTS AT SEVERAL CORRODED METAL LINTELS AT SEVERAL FLOORS OVER MAIN ENTRANCE WALKWWAY. REMEDY: REPAIR AND/OR REPLACE
Aug 14, 2021 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN A CODE COMPLIANT MANNER. EXP1 EAST ELEVATION EXTERIOR WALL DISPLAYS SUBSTANIAL CRACKS AT PARAPET WALL LEVEL AND DEGRADED MORTAR AND LINTELS AT TOP FLOOR WINDOWS. REMEDY: MAINTAIN BLDG IN A CODE COMPLIANT MANNER. TAKE AND PROVIDE SAFETY MEASURES
Aug 3, 2021 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILIRE TO COMPLY WITH COMMISSIONER'S ORDER 313183(052620CLLF02AV) ISSUED ON 05/29/2020. AS OF 08/03/2021 OWNER HAS NOT COMPLIED WITH IMMEDIATE CURE ORDER. REMEDY: IMMED COMPLY WITH CODE AND COMMISSIONER'S ORDERS
Jul 30, 2021 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BUILDING EXTERIOR WALLS OR APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT EXP 1, EAST ELEV.(WADSWORTH AVE), BRICK-MASONRY SECTION ABOUTH 5FL SEPERATING FROM STRUCTURE. CRACKED MASONRY SECTION AT 5FL LEVEL. LOOSE BRICKS AND OPEN BRICK JOINTS AT 5FL. SEVERELY BENDED- CORROED WINDOW LINELS. REMEDY: REPAIR DAMAGE FACADE
May 29, 2020 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN EXTERIOR MASONRY FACADE AND APPURTENANCES. AT TIME OF INSPECTION MASONRY FACADE OBSERVE DEFECTS AT MULTIPLE LOCATIONS REMEDY: MAINTAIN EXTERIOR MASONRY FACADES AND APPURTENANCES, PROVIDE AND MAINTAIN SAFETY MEASURES, REPAIR DAMAGED FACADE, COMPLY WITH CODE
Jun 27, 2018 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Mar 16, 1999 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
May 4, 1998 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Feb 10, 1997 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED