Manhattan East Midtown-Turtle Bay
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
17 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Sep 6, 2019 | V*-DOB VIOLATION - DISMISSED | ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST |
| Sep 15, 2017 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST |
| Dec 15, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 1, 2016 | V-DOB VIOLATION - ACTIVE | EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED | FAILURE TO PERFORM CATEGORY 5 INSPECTION |
| Jun 10, 2015 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST |
| Apr 3, 2015 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 31, 2014 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST |
| Mar 31, 2014 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST |
| Oct 3, 2012 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 1, 2012 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST |
| Jan 18, 2011 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 31, 2009 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED |
| May 19, 2009 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROV ED AMENDMENTS PLANS DO NOT PROVIDE ADEQUATE DETEINS IN REGARD TO REMOV AL AND THE REPLACING OF FLOOR JOIST AND THE SEQUENCE ON HOW TO COMPLET E IT PLANS ALSO LACK STRUCTURAL DETAILS THRUOUT SITE REMEDY: CONFORM T O APPROVED DOCUMENTS OR AMENDMENTS SWO IN PLACE VIO#051609CEX02GYG |
| May 16, 2009 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STOP ALL WORK FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRICITON OPERATIONS NOTED: BUILDING IS EXISTING 4 STORY TO BE 5 ST ORY AT TIME OF INSPECTION I DID OBSERVE NO PROTECTION ON ROOF FOR ADJO INING PROPERTIES AT EXP# 2 OR FOR EXP# OF BUILDING WORK BEING PERFORME D ON ROOF REMEDY: STOP ALL WORK PROTECT PUBLIC & PROPERTY |
| Jan 1, 2009 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Nov 20, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | INADEQUATE DETAILS ON APPROVED PLANS FOR SEQUENCINGOF REPLACEMENT OF S TRUCTURAL JOISTS & BEAMS UNDER "BASEMENT" FLOOR AND FOR TEMPORARY SHOR ING AS NEEDED ALT1 PERMIT #110329519 REMEDY: AMEND PLANS TO SHOW REQUIRED TEMPORARY SHORING AND JOIST REPLA CMENT SEQUENCING/PROCEEDURE INCLUDE CONNECTION & AN CHARGE DETAILS |
| Nov 18, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV ED AMENDMENTS PLANS SHOW TYPE 2 PARTITION CONSISTING OF 3 5/8 INCH SHE ETROCK DEMO PLANS INDICATE TYPE 2 PARTITION TO REMAIN TYPE 2 PARITION IS STAIR HALL PARTITIONS 3RD FLOOR IS OCCUPIED REMEDY: STOP ALL WORK CONFORM TO APPROVED DOCUMENTS OR AMENDMENTS CALL |