NYC Building Report

Manhattan Upper East Side-Yorkville

231 East 94 Street, Manhattan

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

46 records

Date Status Type Summary
Oct 30, 2024 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jul 10, 2024 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
May 29, 2024 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Apr 17, 2024 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Mar 20, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMER WORK ORD. EXPOSED-REBAR/STEEL BEAM FROM CEILING 3 LEV) SPALLING CONCRETE EXP/STEEL BEEAM FROM CEILING 4 FL LEV.SEVERAL LOC CAUSING IMMEDIATE HAZARD TO TRAFFIC. REMEDY:OWNER TO RETAIN A NYS REG DESIGN PROF TO IMMED INSTALL OF SAFETY MEASURES.ALL WORK REPORTED AS DAILY PROGRESS REP TO STRUCTURE@BUILDINGS.NYC.GOV
Jan 29, 2024 V-DOB VIOLATION - ACTIVE IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL PROVIDE SIDEWALK SHED AT ENTIRE FRONT PF PREMISES TO SAFEGUARD THE PU BLIC AND PROPERTY
Jan 27, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL THE BRICK VANEER IS CRACKED,LOOSE,MISSING MORTAR IN VARIOUS LOCATIONS. THE INTERIOR CONCRETE SLABS ARE DEFECTIVE ON ALL FLOORS IN VARIOUS LOCATIONS WITH REBAR SHOWING CONCRETE MISSING SPALLING AT TIME OF INSPECTION.
Dec 22, 2021 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 22, 2021 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
May 20, 2019 V*-DOB VIOLATION - DISMISSED EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED FAILURE TO PERFORM CATEGORY 5 INSPECTION
May 20, 2019 V*-DOB VIOLATION - DISMISSED EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED FAILURE TO PERFORM CATEGORY 5 INSPECTION
Sep 21, 2017 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Sep 15, 2017 V*-DOB VIOLATION - DISMISSED EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
Sep 15, 2017 V*-DOB VIOLATION - DISMISSED EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
Oct 5, 2015 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 5, 2015 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 16, 2014 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 16, 2014 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
May 30, 2014 V*-DOB VIOLATION - DISMISSED ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
Dec 10, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Dec 10, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 30, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 30, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 25, 2012 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 25, 2012 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 11, 2011 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 11, 2011 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jan 14, 2009 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jan 14, 2009 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 29, 2005 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 29, 2005 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 12, 2004 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 12, 2004 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 27, 2001 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 1F4486
Mar 27, 2001 V-DOB VIOLATION - ACTIVE E-ELEVATOR ELEVATORREQUIRED 1F4487
Mar 27, 2001 V-DOB VIOLATION - ACTIVE E-ELEVATOR ELEVATORREQUIRED 1F4486
Mar 27, 2001 V-DOB VIOLATION - ACTIVE E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 29, 2000 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 1F4486
Aug 29, 2000 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 1F4487
Jan 20, 1999 V*-DOB VIOLATION - DISMISSED LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL
Apr 17, 1995 V*-DOB VIOLATION - DISMISSED LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL
Sep 9, 1993 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Aug 3, 1990 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (37)THE ELECTRICAL PIPE CONNECTED TO THE CONTROLLER
Aug 3, 1990 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (74)LADDER FOR THE MOTOR ROOM
Sep 21, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (28,29)CLEAN AND SEAL OIL LEAK & MAIN MACHINE (34)REPAIR CAR FLOOR (35)REPAIR INTERLOCKS, LOCK PINS (51)PROVIDE ADEQUATE PERMANENT LIGHTING IN MOTOR ROOM. (FIXED RECEPTACLES)
Sep 21, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (34)REPAIR CAR FLOOR. (35)REPAIR INTERLOCKS,LOCK PINS (46)REPAIR BROKEN WINDOWS (51)PROVIDE ADEQUATE LIGHTING IN MOTOR ROOM (PERMANENT,FIXED LIGHT RECEPTACLES)