Manhattan Murray Hill-Kips Bay
213 Rear E East 26 Street, Manhattan
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 1-00907-0010), so they can include other buildings on the same lot.
219 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Aug 10, 2026 | B | INVALID CERTIFICATION | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL AT EAST WALL AT PUBLIC HALL STAIRS, 1st STORY |
| Aug 10, 2026 | A | CIV14 MAILED | B | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 13, 2026 | A | NOV SENT OUT | Not available | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WALLS ERECTED CREATING AN ADDITIONAL BULKHEAD AT THE ROOF. |
| Jul 13, 2026 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BASEMENT |
| Jul 13, 2026 | C | NOV SENT OUT | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE FLAPPER AT BOILER ROOM |
| Jul 13, 2026 | A | NOV SENT OUT | Not available | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WALLS ERECTED FROM FLOOR TO CEILING, CREATING ROOMS AND CONVERTING APARTMENT B INTO A DUPLEX APARTMENT. AT CELLAR |
| Jul 13, 2026 | A | NOV SENT OUT | 4C | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF CEILING PIERCING AND ERECTING A METAL SPIRAL STAIR CASE LEADING TO A BULKHEAD IN THE 2nd ROOM FROM EAST LOCATED AT APT 4C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jul 13, 2026 | A | NOV SENT OUT | B | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD FLOOR PIERCED CREATING METAL STAIRS CASE FROM 1ST STORY APARTMENT TO CELLAR CREATING ILLEGAL DUPLEX APARTMENT IN THE 2nd ROOM FROM NORTH LOCATED AT APT B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 13, 2026 | C | VIOLATION CLOSED | A | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM ALLOWABLE TEMP OF 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 13, 2026 | B | CIV14 MAILED | A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 13, 2026 | B | CIV14 MAILED | 4C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AND MORTAR JOINTS AT NORTH, SOUTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 4C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jul 13, 2026 | B | CIV14 MAILED | 4C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE BATHROOM LOCATED AT APT 4C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jul 13, 2026 | B | NOV SENT OUT | Not available | § 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS (WATER CLOSET AND WASH BASIN) AT CELLAR |
| Jul 13, 2026 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT CELLAR |
| Jul 13, 2026 | B | INVALID CERTIFICATION | Not available | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT CELLAR |
| Jul 1, 2026 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BASEMENT |
| Jul 1, 2026 | B | NOV SENT OUT | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF PATIO FURNITURE AND HOUSEHOLD ITEMS AT ROOF |
| Jul 1, 2026 | B | NOV SENT OUT | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Jul 1, 2026 | A | NOV SENT OUT | Not available | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION LAUNDRY ROOM CREATED AT PUBLIC HALL, 4th STORY |
| Jul 1, 2026 | B | NOV SENT OUT | Not available | § 53,187,231 M/D LAW & DEPT RULES & REG. PROVIDE MEANS OF EGRESS FROM YARD TO STREET BY FIREPROOF PASSAGEWAY FOR WHICH APPLICATION MUST BE FILED FOR APPROVAL,OR BY UNLOCKED DOOR OR GATE IN FENCE TO ADJOINING PREMISES WITH CONSENT OF ADJACENT OWNER. |
| Jul 1, 2026 | C | NOV SENT OUT | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Jul 1, 2026 | A | NOV SENT OUT | Not available | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE |
| Jul 1, 2026 | A | NOV SENT OUT | Not available | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD DECK AND FENCE AT ROOF |
| Jun 18, 2026 | C | NOV SENT OUT | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT ENTRANCE DOOR TO BUILDING , 1st STORY |
| Jun 16, 2026 | C | NOV SENT OUT | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR |
| Apr 24, 2026 | B | NOV SENT OUT | A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Apr 24, 2026 | B | NOV SENT OUT | A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING, SOUTH AND WEST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Apr 24, 2026 | B | DEFECT LETTER ISSUED | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FEET AT SOUTH AND WEST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Apr 22, 2026 | B | INVALID CERTIFICATION | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10SQFT AT SOUTH AND WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18804694 ISSUED 22-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Apr 22, 2026 | A | VIOLATION CLOSED | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10SQFT AT SOUTH AND WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Apr 9, 2026 | A | NOV SENT OUT | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Apr 9, 2026 | B | DEFECT LETTER ISSUED | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FEET AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Apr 9, 2026 | B | NOV SENT OUT | A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 28, 2026 | B | NOV SENT OUT | 3B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE BATHROOM LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 28, 2026 | B | NOV SENT OUT | 3B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 28, 2026 | B | VIOLATION DISMISSED | 3B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 28, 2026 | B | NOV SENT OUT | 3B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 28, 2026 | B | VIOLATION DISMISSED | 3B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 24, 2026 | B | NOTICE OF ISSUANCE SENT TO TENANT | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LEES THEN 10SQ FEET AT SOUTH AND WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18735350 ISSUED 24-MAR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Mar 24, 2026 | A | VIOLATION CLOSED | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LEES THEN 10SQ FEET AT SOUTH AND WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 24, 2026 | C | VIOLATION DISMISSED | A | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 24, 2026 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTOR JOINTS AT NORTHEAST CORNER EXTERIOR WALL , 2nd STORY |
| Mar 24, 2026 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTOR JOINTS AT NORTHEAST CORNER EXTERIOR WALL , 3rd STORY |
| Mar 24, 2026 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTOR JOINTS AT NORTHEAST CORNER EXTERIOR WALL , 4th STORY |
| Mar 24, 2026 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQ FEET AT SOUTH AND WEST WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 21, 2026 | B | NOTICE OF ISSUANCE SENT TO TENANT | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18728075 ISSUED 21-MAR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Mar 21, 2026 | A | VIOLATION DISMISSED | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 21, 2026 | C | VIOLATION DISMISSED | A | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE LIMIT OF 130 DEGREES FAHRENHEIT IN THE ENTIRE APARTMENT LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 21, 2026 | A | VIOLATION CLOSED | A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Feb 23, 2026 | C | VIOLATION DISMISSED | A | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDING THE MAXIMUM ALLOWABLE TEMPERATURE OF 130F AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |