| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Mar 15, 2023 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Feb 15, 2022 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Feb 14, 2020 | C | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 2ND, 3RD AND 7TH MARBLE RISERS FROM BOTTOM UP AT PUBLIC HALL STAIRS, 2nd STORY |
| Nov 14, 2019 | B | VIOLATION DISMISSED | 3W | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 14, 2019 | C | VIOLATION DISMISSED | 3W | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR SHUTOFF VALVE IN THE KITCHEN LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 28, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS BUILDING FRONT |
| Mar 28, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT ENTRANCE DOOR TO THE BUILDING 1 LITE |
| Mar 25, 2019 | A | VIOLATION CLOSED | Not available | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| Mar 25, 2019 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING AT PUBLIC HALL, 1st STORY |
| Mar 25, 2019 | A | VIOLATION CLOSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| Mar 25, 2019 | A | VIOLATION CLOSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORY |
| Mar 25, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WIRE GLASS AT STREET ENTRANCE DOOR TO BUILDING AT PUBLIC HALL, 1st STORY |
| Mar 25, 2019 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WALLS AT PUBLIC HALL, 2nd STORY |
| Mar 25, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING AND WALLS AT PUBLIC HALL, 2nd STORY |
| Mar 25, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR AT PUBLIC HALL, 2nd STORY |
| Nov 6, 2017 | I | VIOLATION DISMISSED | Not available | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED. |
| Oct 9, 2013 | B | VIOLATION CLOSED | 3W | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SECONDARY EXIT DOOR SEALED SHUT IN THE 1st ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 9, 2013 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR JOINTS FROM BOTTOM OF 2ND STORY WINDOWS UP TO ROOF AT FRONT OF BUILDING |
| Oct 9, 2013 | A | VIOLATION CLOSED | Not available | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES OF FIRE ESCAPE AT FRONT OF BUILDING |
| Oct 9, 2013 | C | VIOLATION CLOSED | Not available | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DROP LADDER AT FIRE ESCAPE AT FRONT OF BUILDING |
| Oct 9, 2013 | C | VIOLATION DISMISSED | 3W | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; RELACE SCREWS IN THE 4th ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 9, 2013 | C | VIOLATION DISMISSED | 3W | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; REPLACE SCREWS IN THE 1st ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 9, 2013 | A | VIOLATION CLOSED | 3W | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ESCUTCHEON PLATE AROUND STEAM RISER AT CEILING AND FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 9, 2013 | A | VIOLATION CLOSED | 3W | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ESCUTCHEON PLATE AROUND STEAM RISER AT FLOOR AND CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 9, 2013 | B | VIOLATION CLOSED | 3W | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING RADIATOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 9, 2013 | A | VIOLATION CLOSED | 3W | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION FIRE PROOF DOOR SECONDARY EXIT DOOR SEALED SHUT IN THE 1st ROOM FROM NORTH LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 5, 2013 | B | VIOLATION DISMISSED | Not available | SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 4TH STORY AT NORTH FIRE ESCAPE |
| Oct 5, 2013 | B | VIOLATION CLOSED | 3W | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SECONDARY EGRESS DOOR PAINT SHUT IN THE 4th ROOM FROM EAST LOCATED AT APT 3W, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Oct 5, 2013 | C | VIOLATION DISMISSED | 3W | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 3; IN THE ENTIRE APARTMENT LOCATED AT APT 3W, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Oct 5, 2013 | C | VIOLATION CLOSED | 3W | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR VALVE IN THE KITCHEN LOCATED AT APT 3W, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Oct 5, 2013 | B | VIOLATION DISMISSED | Not available | SECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF TWO BICYCLES AT PUBLIC HALL, 4th STORY |
| Oct 5, 2013 | C | VIOLATION CLOSED | Not available | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR AT PUBLIC HALL, 4th STORY |
| Oct 5, 2013 | C | VIOLATION CLOSED | Not available | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING DROP LADDER AT NORTH AT FIRE ESCAPE |
| Aug 22, 2012 | B | VIOLATION DISMISSED | Not available | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED |