Sep 12, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EXPOSURE#1 MULTI-WYTHE BRICK & STEEL FRAMED 3-STORY BLDG W BRICK MASONRY BEARING WALLS & WOOD JOISTS TEMPORARILY STABILIZED UNDER EMERGENCY WORK, WITH NON-COMPLIANT ELEMENTS. REMEDY: FAILURE TO COMPLY W COMMISSIONER'S ORDR 4 VIO #031925CE10203PT. COMPLY WITH ORDER BY 12/31/25
Jun 17, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EXP#1 BRICK & STEEL FRAMED WALL TEMP STABILIZD UNDR EMER WRK. W. NON- COMPLIANT ELEMENTS REMAINING. DOMINIC CULLEN, PE, RECOMMENDS PLUMBNESS SURVEY ON 6/12/25. REMEDY: COMPLY W CODE, BY 6/30 PROVIDE PLUMBNESS SURVEY,SIGNED & SEALED BY NYS LICENSED PROF'L LAND SURVEYOR.RETAIN NYS PE TO ESTABLISH SCOPE & SUPERVISE SURVEY PROGRAM
Mar 19, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EXPOSURE 1 MULTI-WYTHE BRICK & STEEL FRAMED 3-STORY BLDG WITH BRICK MASONRY BEARING WALLS & WOOD JOIST TEMPORARILY STABILIZED UNDER EMERGENCY WORK, WITH NON-COMPLIANT ELEMENTS. REMEDY: COMPLY WITH CODE RETAIN NYS RDP & GC TO BRING EXPOSURE 1 INTO COMPLIANCE. FILE DOCS FOR REPAIR. COMPLETE WORK BY 06/30/2025
Mar 19, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EXPOSURE#1 MULTI-WYTHE BRICK & STEEL FRAMED 3-STORY BLDG W. BRICK MASONRY BEARING WALLS & WOOD JOISTS TEMPORARILY STABILIZED UNDER EMERGENCY WORK, WITH NON-COMPLIANT ELEMENTS. REMEDY: COMPLY W.CODE RETAIN NYS RDP & GC TO BRING EXPOSURE#1 INTO COMPLIANCE. FILE DOCS FOR REPAIR. COMPLETE WORK BY 06/30/25
Mar 19, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EXPOSURE#1 MULTI-WYTHE BRICK & STEEL FRAMED 3-STORY BLDG.W. BRICK MASONRY BEARING WALLS & WOOD JOISTS TEMPORARILY STABILIZED UNDER EMERG ENCY WORK, WITH NON-COMPLIANT ELEMENTS. REMEDY: COMPLY W. CODE, DO MONTHLY INSPECTIONS OF EXP#1. MAKE PE REPORTS AVAILABLE, IF REQUESTED
Mar 19, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL BLDG NON-COMPLIANT DUE TO UNCERTIFD/UNDOCUMENTD SOE,FO & UNDERPINNING AT EXP#2 BY 188 GRAND ST.WRK CONTRARY.TO PERMIT PER 7/25/24 RPT BY STUART GOLD,PE,(3)TEST PITS FOUND UNCERTIFD U/PINNG,FO ELEMNTS ALONG LOT LINE. REMEDY: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER IN DOB VIO #082024CE10201PT-CONTROL #376301.COMPLY W ORDR BY.8/1/25
Mar 6, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK: EXPOSURE #1 FACADE UNSTABLE DURING DEMOLITION AT 188 GRAND ST. WALL HAS LOOSE BRICKS & BULGING, POSES DEBRIS & COLLAPSE HAZARD. REMEDY: RETAIN NYS PE 4 EXP#1 MONITORNG PLAN,INCLUDG THRESHOLDS,LOCATIONS.& REPORTING BY 3/7, INSTALL EQUIPMENT, BASELINE READINGS BY 3/10/25
Mar 6, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK: EXPOSURE #1 FACADE UNSTABLE DURING DEMOLITION AT 188 GRAND ST. WALL HAS.LOOSE BRICKS & BULGING, POSES DEBRIS & COLLAPSE HAZARD. REMEDY: FAILURE TO COMPLY W. COMMISSIONER'S ORDER, VIOLATION # 022025CE10202PT. COMPLY W ORDER BY 03/07/25 & 03/31/25 RESPECTIVELY
Feb 20, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK: EXPOSURE#1 FACADE UNSTABLE DURING DEMOLITION AT 188 GRAND ST. WALL HAS LOOSE BRICKS & BULGING, POSES DEBRIS & COLLAPSE HAZARD. REMEDY: COMPLY W. CODE, RETAIN NYS PE, GC & CS TO STABILIZE EXP#1. SUBMIT CONSTRUCTION DOCS. COMPLETE BY 3/3/25. DEP & DOT PERMITS FILE DOB NOW
Feb 20, 2025 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK: EXPOSURE#1 FACADE UNSTABLE DURING DEMOLITION AT 188 GRAND ST. IN-PLACE PUBLIC PROTECTION DOESN'T ADEQUATELY PROTECT FROM FACADE HAZARD. REMEDY: COMPLY W. CODE, RETAIN NYS PE & GC TO EXTEND OVERHEAD PUBLIC PROTECTION ACROSS EXPOSURE # 1. COMPLETE BY 2/21/25 OBTAIN DOT APPROVAL
Oct 4, 2024 V*-DOB VIOLATION - DISMISSED LANDMK-LANDMARK NONE LANDMK-LANDMARK NONE
Aug 20, 2024 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL BLDG NON-COMPLIANT DUE2 UNCERTIFD/UNDOCUMENTD SOE, FO & UNDERPINNING @ EXP#2 BY 188 GRAND ST. WRK CONTRARY2PRMT,PER 7/25/24 RPT BY STUART GOLD,PE,(3)TEST PITS FOUND UNCERTIFD U/PINNG,FO ELEMNTS ALONG LOT LINE REMEDY: COMPLY W CODE, PE TO EVAL FNDN/SUBGRADE.SUBMIT CONSTRUCTN DOCS & INSPECTION PLAN, FINISH WORK/SIGN-OFF BY 1/20/25
Jan 10, 2024 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL PREMISES RENDERRED NON COMPLIANT DUE TO PARTIAL MASONRY COLLAPSEAT AD JACENT PROPERTY KNOWN AN 188 GRAND STREET. SAFETY ZONE FOR DEFECTIVE B UILDING TO EMCOMPASS SAID ADDRESS TO INCLUDE 1ST FLOOR COMMON SPACE