Apr 25, 2023 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 26, 2021 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. 30LF OF CMU IN REAR YARD APPROX 5'-6" TALL IS HEAVILY OUT OF PLUMB +/- 3" AND IN DANGER OF COLLAPSE TO REAR YARD OF 16 WEST 82ND STREET WHICH IS CURRENTLY UTILIZED AS RECREATION AREA CREATING A HAZARDOUS CONDITION.
Sep 10, 2020 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL THE DEPARTMENT INTENDS TO REVOKE THE APPROVAL AND PERMIT FOR REASONS SET FORTH ON THE ATTACHED OBJECTION SHEET DATED AUGUST 26, 2020 WORK (0%) COMPLETED.
Aug 25, 2020 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL RECENT MOVEMENT OBSERVED TO EXP 2-EAST WALL AND CONDITIONS DESCRIBED IN VIOLATION#101019FEU10701BS HAVE WORSENED WITHOUT REQ'D MONITORING PER VIOLATION INSTALLED.NYSPE IMMED EVAL ENTIRE BLDG& PROVIDE STRCTL STABL PRMT.REPT TO INCLD RECOMMENDATIONS BLDG SAFETY OCCUPIED DURING RPRS.IMMED INSTL MONITORS PER PE.PROVIDE SCHEDULE REPRS BY 9/4/2020
Oct 10, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:EXP1 WALL IN DISREP.MULTI LOCATION BUBBLING COATING/PAINT,CRACKED STONE,DETERIORATED STONE,SPALLING STONE,AND OPEN JOINTS AT EXP1 WALL STRUCTURAL STONE LINTELS CRACKED AT 1ST FL & 3FL WINDOWS@EXP1.QEWI TO EVAL ENTIRE FRONT FAÇADE&DESIGN REPAIRS UNDER PERMIT.FILE BY 12/16/19 OBTAIN PERMIT&STRT WRK BY 12/30/19.CMPL REPRS&SIGNOFF PERMIT BY 4/6/20
Oct 10, 2019 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTM:SETTLEMENT OF EXP2 WALL.THRU-WALL STEP CRACKS@EXP2 WALL EXP2&4 REAR YARD CMU SITE WALLS STEP CRACKS EXCESSIVE MOVEMENT AND OUTWARD DISPLACEMENT.EXP3 WALLS DIAGONAL CRACKS IN MULTI LOCAT.IMMED EVALUATE BLDG SUBMIT GEOTECH REPORT BY 11/22/19.IMMED MONITOR EXP2 WALL.START WORK UNDER PERMIT BY 3/16/20.CMPL ALL WRK&REPRS & S/O PRMTS BY 8/28/20
Apr 6, 2018 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
May 17, 2017 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Apr 7, 2017 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAIL TO MAINTAIN 4STORY PLUS BSMT WOOD FRAME MASONRY BEARING WALL BLDG EXP2 EAST WALL HAS 2 LARGE VERT CRACKS.RETAINING WALL IN REAR YARD AT EXP2 EAST WALL HAS DISPLACED BRICK.FORMER PARTY WALL AT EXP2 WALL HAS NO TIES TO FLRS.REMEDY:OWNER RETAIN NYS PROF ENG'R EVAL EXP2 WALL& RETAIN WALL.PROV ENG'RS REPORT&REPAIR DWGS BY 5/15/17
Mar 1, 2013 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Dec 13, 2011 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Dec 31, 2009 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
Jan 19, 2007 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jan 6, 2006 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Feb 27, 2001 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Feb 7, 2000 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jun 2, 1999 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL
Mar 16, 1999 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
May 4, 1998 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 18, 1993 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED