Manhattan Upper East Side-Carnegie Hill
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
21 records
| Date | Status | Type | Summary |
|---|---|---|---|
| May 14, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.THE GARAGE SLABS ON BEAMS ON THE2ND,3RD,&4TH FLS WERE SEVERELY DETERIORATD,SPALLD&SAGGD W/CRCKS HOWEVER,SOME OF THESE AREAS LACKD SHORNG.FAIL TO COMPLY W/COMMISS ORDR 042224FEU10801ZT DATD 4/22/24 REQ.OWNR TO STRT BLDG RPR UNDR PRMT IMMED COMPLY TO RPR BLDG |
| Apr 22, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.THE GARAGE SLABS ON BEAMS ON THE 2ND,3RD,&4THFLS WERE SEVERELY DETERIORATD,SPALLD&SAGGD W/CRCKS HOWEVER,SOME OF THE AREAS LACKD SHORNG.FAIL TO COMPLY W/COMMISS ORDR 042224FEU10801ZT DATD 4/22/24 REQ.OWNR TO STRT BLDG RPR UNDR PRMT IMMED COMPLY TO RPR BLDG |
| Jul 19, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | OBSERVED SECTION OF CONCRETE MISSING AROUND BEAMS AND EXPOSING REBAR. STEEL BEAMS AND REBAR HAS RUST AND OXIDATION AT ALL LEVEL AND TEMPORARY SHORING INSTALLED AROUND ALL SECTION ALL THESE AREAS |
| Dec 7, 2020 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 3, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 8, 2014 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| May 30, 2014 | V*-DOB VIOLATION - DISMISSED | ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST |
| Apr 9, 2014 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 22, 2013 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 13, 2011 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST |
| Aug 16, 2011 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 6, 2010 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 6, 2007 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| May 16, 2005 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 28, 2003 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1F447 |
| Mar 30, 2001 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1F4447 |
| Aug 22, 2000 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 1F4447 |
| Feb 13, 1990 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 18-INTERLOCKS JUMPED, 40-5 YEAR SAFETY TEST,LEASE ARE UNTIL ITEMS 15 AND 18 ARE REPAIRED |
| Mar 3, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (34,35,36) REMOVE ALL PUMP INTERLOCKS (51) CONDUCT AND TAG THE SAME WITH ALL MESESSAGE TEST (52) PROVIDE A LOCK W/AVAILABLE KEY FOR THE MOTOR ROOM DOOR (35)COVERS (46) CAR TOP CLEAN |
| Mar 3, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (#34,35, & 36)REMOVE ALL JUMP INTERLOCKS.(51)CONDUCT AND TAG THE SAME WITH ALL NECESSARY TEST.(52)PROVIDE A LOCK WITH AVAILABLE KEY FOR THE MOTOR ROOM DOORS.(35)COVERS.(46)CAR TOP CLEAN |
| Jan 6, 1989 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |