| Dec 5, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | BUILDING HAS BEEN OBSERVED HAVING SPECIAL INSPECTOR JAY KAVI (P.E) REMOVED FROM APPLICATION M01156375-I1 DUE TO SURRENDERING OF FILING PRIVILEGES. NEW SPECIAL INSPECTOR MUST SUPERSEDE PREVIOUS INSPECTOR TO PREVENT REVOCATION OF THE PERMIT FOR THIS JOB. |
| Dec 5, 2025 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BUILDING HAS BEEN OBSERVED HAVING SPECIAL INSPECTOR JAY KAVI (P.E) REMOVED FROM APPLICATION M01156335-I1 DUE TO SURRENDERING OF FILING PRIVILEGES. NEW SPECIAL INSPECTOR MUST SUPERSEDE PREVIOUS INSPECTOR TO PREVENT REVOCATION OF THE PERMIT FOR THIS JOB. |
| Dec 5, 2025 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BUILDING HAS BEEN OBSERVED HAVING SPECIAL INSPECTOR JAY KAVI (P.E) REMOVED FROM APPLICATION M01156317-I1 DUE TO SURRENDERING OF FILING PRIVILEGES. NEW SPECIAL INSPECTOR MUST SUPERSEDE PREVIOUS INSPECTOR TO PREVENT REVOCATION OF THE PERMIT FOR THIS JOB. |
| Dec 5, 2025 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BUILDING HAS BEEN OBSERVED HAVING SPECIAL INSPECTOR JAY KAVI (P.E) REMOVED FROM APPLICATION M01039963-I1DUE TO SURRENDERING OF FILING PRIVILEGES. NEW SPECIAL INSPECTOR MUST SUPERSEDE PREVIOUS INSPECTOR TO PREVENT REVOCATION OF THE PERMIT FOR THIS JOB. |
| Oct 30, 2024 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 23, 2024 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION |
| Aug 23, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED IN APT 11, KITCHEN CEILING SAGGING, NUMEROUS HORIZONTAL CRACKS ALONG INTERIOR PARTITION AT CORNERS OF WALL AND CEILING. CLOSET DOOR FRAME IN KITCHEN LEANING AND OUT OF PLUMB. AREAS THROUGHOUT APARTMENT HAS FLOOR NOT LEVEL. |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION |
| Jul 21, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| May 12, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Feb 24, 2017 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT |
| Oct 1, 2015 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT |
| Jan 3, 2008 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 3, 2008 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 5, 1990 | V-DOB VIOLATION - ACTIVE | ES-ELECTRIC SIGNS NONE | ES-ELECTRIC SIGNS NONE |