NYC Building Report

Brooklyn

BIN 3395734

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

10 records

Date Status Type Summary
Jan 28, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER.THE STEEL ROOF TRUSSES HAVE WARPED AT MIDDLE SECTION&STRCTRLLY CMPRMSD.THE DAMAGED ROOF SECTIONS POSE A RISK OF COLLAPSE&DANGR TO ADJ UNDAMAGED BLDG SECTIONS.OWNR TO IMMED 1.RTAIN NYSPE&DEMO ENDRSD GC TO IMMED PRTLLY DEMO THE MIDDLE SECTION OF THE LDG DMGD BY FIRE.INSTLL TEMP
Jan 23, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK.BLDG SUSTAIND DMG DUE TO FIRE ON 1/21/26 THE STEEL ROOF TRUSSES HAVE WARPED@MIDDLE SECTION.OPEN ROOF&LOOSE METAL ROOF DECK IN DANGER OF DETACHNG&FLYNG OFF THE BUILDING.IMMED RMVE/SECURE LOOSE SECTIONS OF ROOF DECK UNDR PRMT& CONTINUOUS SUPERVISION OF PE.PE TO SBMT MEANS&METHDS FR REVW
Jan 22, 2026 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL SEAL ALL FIRE DAMAGED ACCESSIBLE OPENINGS TO SAFEGUARD THE PUBLIC AND PROPERTY
Jan 21, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL AT TIME OF INSPECTION OBSERVED SMOKE, FIRE AND WATER DAMAGE THROUGHOUT PREMISES, HORIZONTAL METAL SUPPORT BEAM DAMAGED, ROOF OPEN TO THE ELEMENTS DUE TO FIRE. VACATE COMMERCIAL STORAGE SPACES 8,9,10,11,12,13,14,15 AND 16.
Jan 21, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ENGINEERS REPORT REQUIRED-AT TIME OF INSPECTION OBSERVED SMOKE, FIRE AND WATER DAMAGE THROUGHOUT PREMISES, HORIZONTAL METAL SUPPORT BEAM DAMAGED, ROOF OPEN TO THE ELEMENTS DUE TO FIRE.
Jan 10, 2023 V*-DOB VIOLATION - DISMISSED COMPBLD-STRUCTURALLY COMPROMISED BUILDING NONE FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISE
Dec 14, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTM DUE TO FIRE.BLDG NAMED 700 COLUMBIA ST.BLDG #200.ADJCNT BLDG #211 SUFFRD A FIRE.LRGE EXHAUST FAN DISLODGED FRM FIRE BLDG&STRCK ROOFTOP GUARDRAIL,PARAPET,&ROOFTOP MECHANICAL OF BLDG#200.IMMED CLOSE RF AREA UNDER DMGD PARAPET&MECH ROOM DOOR NYSPE STRCTRL ENGNEER TO EVAL PRAPET & GUARDRAIL DAMAGE
Dec 14, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Dec 14, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERG WRK-BLDG#211 SUFFERD FIRE ON 12/13/22&SUSTAINED STRCTL DMG.APPRX 75%OF FOOR PART.COLLAPSD OR STEEL FRAMING EXCESSIVELY DEFORM DUE TO FIRE DAMAGE AND MISSING CLADDING AT ALL EXPOSURES IMMED FULL DEMO-COORD W/FDNY&FIRE MARSHL&NYPD.ALL WRK SUPRVS ONSITE PE&BY DM CONTRCT.FILE W/I 2 DAYS.SUBMT M&M TO FEU
Dec 14, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERG WRK-BLDG #211 SUFFERED FIRE ON 12/13/22 &SUSTAIND STRUCTURAL DMG APPRX 75% OF ROOF PARTIALLY COLLAPSED OR STEEL FRAMINGEXCESSIVELY DEFORMED DUE TO FIRE.FIRE DMG&MISSING CLADDING @ ALL EXPOS IMMED INSTL TIGHTBRD FENCE-CLS OFF DRIVWY&SIDWLK TO BLDGS 211 &200 FROM GATE 5 TO WATER.COORD W/NYPD.FILE W/IN 2 DAYS