Brooklyn Bushwick (East)
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 3-03381-0025), so they can include other buildings on the same lot.
74 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Dec 9, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WEST DOOR IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 9, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 9, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 9, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 9, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WEST DOOR IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 9, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WEST CLOSET DOOR IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 5, 2007 | C | VIOLATION CLOSED | Not available | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED |
| Dec 5, 2007 | C | NOT COMPLIED WITH | Not available | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1ST STY PUBLIC HALL |
| Dec 5, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Dec 5, 2007 | B | VIOLATION CLOSED | 3FL | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 7, 2007 | B | NOT COMPLIED WITH | BSMNT | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS IN THE ENTIRE APARTMENT LOCATED AT APT BSMNT |
| May 7, 2007 | B | NOT COMPLIED WITH | BSMNT | SECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, .. IN THE ENTIRE APARTMENT LOCATED AT APT BSMNT |
| Apr 18, 2007 | B | NOT COMPLIED WITH | BLDG | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS ........ IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BLDG |
| Apr 18, 2007 | B | NOT COMPLIED WITH | BLDG | SECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, ....... IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BLDG |
| Mar 20, 2007 | B | NOT COMPLIED WITH | BASE | SECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, , IN THE KITCHEN LOCATED AT BSMT-APT BASE |
| Mar 20, 2007 | B | NOT COMPLIED WITH | BASE | SECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION APT CREATED AT THE BASEMENT LOCATED AT BSMT-APT BASE |
| Mar 20, 2007 | B | NOT COMPLIED WITH | BASE | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS , LOCATED AT BSMT-APT BASE |
| Mar 20, 2007 | B | VIOLATION CLOSED | Not available | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD |
| Jul 21, 2006 | B | NOT COMPLIED WITH | Not available | SECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION INCREASE IN OCCUPANCY BASEMENT CHANGED FORM ORDINARY USE TO CLASS (A) APT. |
| Jul 21, 2006 | B | NOT COMPLIED WITH | Not available | SECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, GAS COOKING RANGE AT BASEMENT |
| Jul 21, 2006 | B | NOT COMPLIED WITH | Not available | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS WATER CLOSET, WASH BASIN , BATHTUB, KITCHEN SINK AT BASEMENT |
| Jul 21, 2006 | B | VIOLATION DISMISSED | BSMT | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER LEAK FROM BASEMENT DOOR AT REAR IN THE KITCHEN LOCATED AT APT BSMT, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 12, 2006 | B | NOT COMPLIED WITH | BSMT | SECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, ... IN THE ENTIRE APARTMENT LOCATED AT APT BSMT, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 12, 2006 | B | VIOLATION DISMISSED | BSMT | SECTION 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES WHERE ILLEGAL AND PROPERLY SEAL PIPE CONNECTIONS ... IN THE ENTIRE APARTMENT LOCATED AT APT BSMT, 1st APARTMENT FROM EAST AT SOUTH |