Brooklyn Crown Heights (South)
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
119 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Sep 26, 2025 | V-DOB VIOLATION - ACTIVE | E-ELEVATOR ELEVATORREQUIRED | UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. CEASE USE ORDER ISSUED FOR THE FOLLOWING ITEM: DAMAGE TO ELECTRONIC COMPONENTS AS A RESULT OF FLOODING. |
| Sep 22, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | UNLAWFUL ACTS OF FAILURE TO COMPLY WITH COMMISSIONER ORDER#070225CPS30 901JL EMERGENCY WORK ORDER ISSUED ON 7/2/25 COMPLAINT#3A20222.AFTER OB SERVATION,CRACKED,SPALLING CONCRETE,EXPOSED REINFORCEMENT & VERTICAL C RACK APPROX 6FT LONG AT CONCRETE WALL CREATED HAZARDOUS CONDITION.REME DY:IMMEDIATELY COMPLY WITH COMMISSIONER ORDER ISSUED ON 7/2/2025 |
| Jul 2, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK-AT TIME OF INSP ON AN OCCUPIED PARKING STRUCT OBSVD @ SUBCELLAR CRACKED/SPALLING CONCRETE,EXPOSED REINFORCEMENT AND VERT CRACK APPROX 6FT W/EXPOSED REINFORCEMENT AT CONCRETE WALL. OWNER TO RETAIN A NYS REG DESIGN PROF TO DIRECT AND SUPERV THE IMMED INSTALLATION OF SAFETY MEASURES AND PROV SHORING TO UNSAFE AREAS |
| Oct 4, 2023 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 4, 2023 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 4, 2023 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Apr 22, 2023 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) |
| Dec 28, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER DUE TO SECONDARY FACADE FAILURE. ON 11/09/2022 A FAILURE OF THE EXTERIOR MASONRY WALL AND BACKUP CMU WALL OCCURRED AT THE 31FL CAUSING IMMED HAZARD TO THE PUBLIC AND PROPERTY. ON 12/23/2022 A SECONDARY FAILURE OCCURRED WHERE WMULT BRICKS FELL REMDY:IMMED INSP AND STABILIZAE ALL OOSE BRICKS & MASONRY ELEMENTS |
| Nov 17, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | ADDITIONAL INFORMATION-ON 11/04/2022 AN APPROX 20'X15' SECTION OF BRICK & CMU BACK UP WALL FAILED FROM THE 31FL FACADE & FELL ON THE 22FL SETBACK. REMEDY: BY CLOSE OF BUSINESS DAY 12/01/2022 PROVIDE COPIES/REPORTS:FORENSIC ENG'R REPORT,ALL AS BUILT DOCS FOR ORINGIANL CAVITY WALL CONST,ARCH DWGS,TEMP BRACING DWGS. SUBMIT REPORTS |
| Nov 17, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | PROVIDE PEER REVIEW-ON 11/04/2022 AN APPROX 20'X15' SECTION OF BRICKS & CMU BACK UP WALL FAILED FROM THE 31FL FACADE & FELL ON THE 22FL SETBACK. MULTIPLE OTHER UNSAFE FACADE CONDITIONS WERE NOTED. REMEDY: OWNER TO PROVIDE NO LATER THAN 12/01/2022 THE NAMES OF 3 NYS LIC DESIGN PROF REG AS QEWI W/KNOWLEDGE & EXPERINCE OF MASONRY FACADE |
| Nov 9, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM FACADE AND APPURTENANCES-ON 11/4/2022 MASONRY FACADE AND BACK UP CMU EALL FAILED FROM 31FL AND FELL ONTO 22FL ROOF. REMEDY: OWNER TO IMMED RETAIN SERVICES OF NYS REG DESIGN PROF W/SONRY FACADE/CAVITY WALL EXPERIENCES TO INSPECT AND EVAL 100% OF ALL BRICKS THAT EXTEND FROM FLOOR TO DETERMINE SAFETY OF SAME AND CAUSE OF FAILURE |
| Nov 9, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER DUE FACADE BRICK AND BACK UP CMU WALL FAILURE & COLLAPSE FROM FL 31. REMEDY: IMMED RETAIN A NYSPE W/EXPERIENCE IN MASONRY FACADE INSPECTION/REPAIR WORK TO INSPECT AND DESING STAB METHODS OF ALL REQ'D FACADE LOCATIONS. IMMED STAB FACADE UNDER FULL TIME SUPV OF PE, PE TO SUBMIT DAILY REPORTS OF FACADE INSP & STAB |
| Nov 4, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER DUE TO FACADE BRICK AND BACK-UP CMU WALL FAILURE & COLLAPSE FROM FL 31. REMEDY: IMMED UNDER FULL TIME SUPERV OF A NYSPE INSTALL TEMP FULL EIGHT WALL TO PREVENT CONTACT W/FAILED/DISTRESSED PERIMETER WALLS,REMOVE/STABILIZE ALL EXTERIOR FACADE MATERIAL & CMU BACK-UP WALL,INSTALL ADD'L SIDEWLK SHED,COMPLY W/ALL ERT & C/D MANDATE |
| Feb 22, 2022 | V*-DOB VIOLATION - DISMISSED | FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED | FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 |
| Apr 29, 2021 | V*-DOB VIOLATION - DISMISSED | EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE | FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 |
| Feb 13, 2021 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Feb 13, 2021 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Feb 13, 2021 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 29, 2020 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2019 |
| Feb 19, 2020 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Feb 19, 2020 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Feb 19, 2020 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jul 30, 2019 | V*-DOB VIOLATION - DISMISSED | EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED | FAILURE TO PERFORM CATEGORY 5 INSPECTION |
| May 20, 2019 | V*-DOB VIOLATION - DISMISSED | EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED | FAILURE TO PERFORM CATEGORY 5 INSPECTION |
| Apr 5, 2019 | V*-DOB VIOLATION - DISMISSED | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST |
| Feb 4, 2019 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Feb 4, 2019 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| May 31, 2018 | V*-DOB VIOLATION - DISMISSED | FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED | FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 |
| May 2, 2018 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Feb 7, 2018 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Feb 4, 2018 | V-DOB VIOLATION - ACTIVE | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED |
| Feb 4, 2018 | V-DOB VIOLATION - ACTIVE | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED |
| Sep 15, 2017 | V*-DOB VIOLATION - DISMISSED | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST |
| Apr 19, 2017 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jan 30, 2017 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Dec 1, 2016 | V*-DOB VIOLATION - DISMISSED | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2015 INSPECTION/TEST |
| Mar 8, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 8, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 8, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 8, 2016 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2015 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2015 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2015 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2014 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2014 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2014 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | E-ELEVATOR ELEVATORREQUIRED | ILLEGAL DISMANTLE |
| Aug 19, 2014 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 24, 2013 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 31, 2013 | V*-DOB VIOLATION - DISMISSED | FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED | FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012 |
| May 2, 2012 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |