| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 25, 2026 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN DOB #061826CE30201PT, ISSUED 6/18/26;COMPLY WITH ALL REQUIREMENTS OF THE AFOREMENTIONED COMMISSIONER'S ORDER. IMMEDIATELY RETAIN PE,CS & GC TO STABLIZE & PROTECT THE SITE & ADJ PROERTIES FROM COLLAPSE HAZARD |
| Jun 18, 2026 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | EMERG. WRK: WOOD JOIST BLDG W/ URM (BRICK) WALLS, COMPROMISED DURING A ALT. WORK, DANGER OF COLLAPSE.EXP 1-4 WALLS UNBRACED, JOISTS SHIFTED, EXP 2 WALL VISIBLY BULGED. DANGER TO PUBLIC & ADJ PROPS.REMEDY:RETAIN PE/CS/GC TO STABILIZE. SUBMIT S&S DOCS BY 9AM 6/22/26.START WORK 6/23/26. DAILY PE INSPECTS. FILE W.IN 48HR |
| Dec 28, 2016 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 28, 2016 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 31, 2014 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 17, 2014 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 1, 2014 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL |
| Sep 26, 2014 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING. FRONT BRICK FACADE WALL IS DETACHED FROM BUIDLING WITH CRACKS AROUND WINDOWS AND CRACK AT CORNER OF EXPOSURE #1 & EXPOSURE #2. REAR PART OF EXPOSURE #2 WALL IS CRACKING & BULGING OWNER TO IMMEDIATELY HAVE LICENSED PE TO EVALUATE ENTIRE BUILDINGM, & OBTAIN PERMIT FOR REPAIR. START REPAIR WORK NO LATER THAN 10/13/14 |