| Apr 21, 2019 | B | NOV SENT OUT | 1A | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE AIRCONDITIONER INSTALLED AT WINDOW USED FOR EGRESS, AT NORTH WALL. IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Apr 21, 2019 | C | VIOLATION CLOSED | 1A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT PLASTER CEILING (AT APPROXIMATETLY( 4SQFT) IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Apr 21, 2019 | C | NOV SENT OUT | 1A | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT DOOR IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | C | VIOLATION CLOSED | 1A | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | C | VIOLATION CLOSED | 1A | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | C | VIOLATION CLOSED | 1A | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | C | VIOLATION CLOSED | 1A | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | C | FALSE CERTIFICATION | 1A | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE FOYER LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | A | NOV SENT OUT | 1A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | A | NOV SENT OUT | 1A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT 1st RADIATOR FROM WEST AT NORTH WALL, 1st RISER FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | B | NOV SENT OUT | 1A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL, EAST WALL, SOUTH WALL, WEST WALL, CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | A | NOV SENT OUT | 1A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT 1st RISER FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | A | NOV SENT OUT | 1A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | A | NOV SENT OUT | 1A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | B | NOV SENT OUT | 1A | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | B | NOV SENT OUT | 1A | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 1, 2019 | B | NOV SENT OUT | 1A | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Feb 20, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BUILDING ENTRANCE FROM STREET AT PUBLIC HALL, 1st STORY |
| Feb 20, 2019 | A | VIOLATION CLOSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| Feb 20, 2019 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY |
| Feb 20, 2019 | A | VIOLATION CLOSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY |
| Dec 25, 2018 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT ALCOVE AT FRONT AT BUILDING |
| Dec 25, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AT ALCOVE AT FRONT OF BUILDING |
| Dec 25, 2018 | B | VIOLATION CLOSED | 2C | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT COURTYARD |
| Oct 27, 2018 | B | NOV SENT OUT | 2A | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT ENTRANCE LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 27, 2018 | A | NOV SENT OUT | 2A | § 27-2005 ADM CODE REFIT ENTRANCE DOOR LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 27, 2018 | B | NOV SENT OUT | 2A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 27, 2018 | B | NOV SENT OUT | 2A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 27, 2018 | B | NOV SENT OUT | 2A | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHTING FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 27, 2018 | B | NOV SENT OUT | 2A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 27, 2018 | B | NOV SENT OUT | 2A | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASHBASIN WASTE LINE IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 27, 2018 | B | NOV SENT OUT | 2A | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTELINE OF WASH BASIN IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT NORTH |
| Sep 27, 2018 | A | NOV SENT OUT | 2A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT NORTH |
| Sep 27, 2018 | A | NOV SENT OUT | 2A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT NORTH |
| Aug 30, 2018 | B | VIOLATION CLOSED | Not available | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE PIPE AT CEILING, SOUTHWEST AT FIRE PASSAGE WAY |
| Aug 30, 2018 | B | VIOLATION CLOSED | Not available | § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING AT SOUTHWEST AT FIRE PASSAGE WAY |
| Aug 30, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF CLOTHING STRUNG ACROSS BALCONIES AT ALL STORIES INCLUDING HOUSEHOLD ARTICLES AT WEST/NORTH AND WEST/SOUTH STACKS |
| Aug 30, 2018 | A | VIOLATION CLOSED | Not available | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT WEST/SOUTH STACK. |
| Aug 30, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROPLADDER OFF GRAVITY HOOK AT SOUTH STACK. |
| Aug 23, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD 1ST FROM BOTTOM OF STAIR AT PUBLIC HALL, 1st STORY |
| Aug 18, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD 1ST FROM BOTTOM UP AT PUBLIC HALL STAIRS, 1st STORY |
| Aug 18, 2018 | A | VIOLATION CLOSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING ON WALL AT PUBLIC HALL, 1st STORY |
| Aug 18, 2018 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING ON WALL AT PUBLIC HALL, 1st STORY |
| Aug 18, 2018 | A | VIOLATION CLOSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| Aug 18, 2018 | A | VIOLATION CLOSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Aug 18, 2018 | A | VIOLATION CLOSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY |
| Jul 24, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD 1ST FROM BOTTOM UP AT PUBLIC HALL STAIRS, 1st STORY |
| Jul 17, 2018 | C | VIOLATION CLOSED | Not available | § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS (RATS) IN GARBAGE RECEPTICALS IN FRONT OF BUILDING |
| Jul 17, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF WINDOW AIR CONDITIONERS ON 2ND AND 4TH STORY BALCONIES AT FRONT OF THE BUILDING EAST STACK |
| Jul 17, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF WINDOW AIR CONDITIONERS ON 2ND, 3RD AND 4TH STORY BALCONIES AT FRONT OF THE BUILDING WEST STACK |