Brooklyn Carroll Gardens-Cobble Hill-Gowanus-Red Hook
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
18 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Oct 13, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 3, 2020 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| May 3, 2020 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Jul 19, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | EMG WRK:DUE TO ONGOING GAS MAIN EXCAV WRK BY NAT GRID ALONG 2AVE EXP 1/2 OF BLDG SUFFER STRCTL DMG@BEAR WALLS CRKS @EXP 1/2 CORNER OUTWARD MOVT OF EXP2 WALL.APPX 35 LF OF WALL UNSTBLE&IS A RISK OF COLLAP.IMMED HIRE PE&CONTR TO EVAL WHOLE BLDG&PROVIDE SHOR FROM GRADE TO ROOF ALONG EXP2.PART DEMO OF EXT WALL EXP2&1.WRK SUPV BY PE.FILE PRMT W/IN 2 DAYS |
| Jul 19, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM:EXT WALLS STATE OF DISREP@ALL EXP. CRKS DETERIOR BRICK OPEN JOINTS OBSERV MULTI LOCAT@ALL EXP.CORROD STEEL LINTELS,SEPARAT BTWN WALL&REAR AT EXP1.APPROX 50'FROM EXP1/2 CRNR.SEPARATION OF WALLS BETWEEN EXP1,3 IMMED RETAIN PE EVAL ALL EXT WALLS&CHIMNEYS.PROVIDE REPAIRS UNDER PRMT FILE BY 9/3/19. STRT WRK UNDER PRMT BY 9/16/19.SIGN OFF BY 12/2/19 |
| Jul 19, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM DUE TO ADJ EXCAV:DUE TO ONGOING GAS MAIN EXCAV WRK BY NAT GRID ALONG 2 AVE EXP2 BLDG DMG.CRKS&MOVT OF SLAB ALONG EXP2.EXP 1/2 BRICK BEAR WALLS LARGE VERT&DIAG CRKS OUTWARD MOVT@EXP2,&PORT OF WALL UNSTBL OWNR RETAIN PE&ENG EVAL ENTIRE BLDG IMMED&DSGN &REPR UND PRMT.FILE JOB BY 8/19/19 OBT PRMT&STRT WRK BY 9/3/19 CMPL REPRS AND S/O BY 11/11/19 |
| Jul 18, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STRUCTURE RENDERED NON-COMPLIANT DUE WHAT APPEARS TO BE NATIONAL GRID OPERATIONS CAUSING A CRACK IN FACADE FROM APPROX. 1" TO 4" W X 15' L AT EXPOSURE 1 ONTO EXPOSURE 2 VACATE COLLAPSE ZONE FORTHWITH. |
| Sep 23, 2014 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY WITH A COMMISSIONER'S ORDER. THE BUILDING IS A WARE- HOUSE-TYPE STRUCTURE WITH A WOOD BOWSTRING TRUSS/ROOF. THE DEPARTMENT SERVED YOU WITH A CURABLE COMMISSIONER'S ORDER (NOTICE OF VIOLATION) TO PRODUCE AN ENGINEER'S REPORT ON YOUR BUILDING. NO ENGINEER'S REPORT HAS BEEN RECEIVED |
| Jun 11, 2014 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | NYC ADMIN CODE OCCUP 2 STORY GARAGE WITH WD BOWSTRING TRUSS ROOF W/I 60 DAYS OF DATE OF VIOLATION,OWNER TO ENGAGE A NYS LICENSED P.E EP WITH WOOD TRUSSES TO PROBE AND EVAL STRUCTURAL SOUNDNESS OF BOWSTRING USING FIELD VERIF,CALCS,PROBES,ECT. EACH TRUSS AND BEARINGS TO BE EVAL IMM SHORED,REPAIR DRWINGS FILLED DOB WITHIN 45 DAYS |
| Apr 28, 2008 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STOP ALL WORK,MAKE SAFE,OBTAIN PERMITS AND APPROVALS,CALL DOB PRIOR TO FURTHER CONSTRUCTION |
| Feb 10, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 10, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jul 25, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 16, 1993 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |