Brooklyn Bedford-Stuyvesant (West)
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
20 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Nov 14, 2025 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| Jul 1, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | ADDITIONAL INFORMATION.PREVIOUSLY THE BLDG WAS IN SEVERE STATE OF DISREPAIR & IS CURRENTLY BEING REPAIRED UNDER PERMIT #B0103882 APPLICANT OF RECORD TO SBMT MONTHLY RPRT TO XCELO@BUILDINGS.NYC.GOV RPRT TO PRVDE STATS OF RPAIRS |
| Apr 17, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND/OR APPURTANCES IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION IT WAS OBSERVED AT EXPOSURE 4 (SOUTH ELEVATION) SPALLING STUCCO, CRACKS ON STUCCO AND MISSING PIECES OF STUCCO. REMEDY: REPAIR AND/OR REPLACE |
| Jan 10, 2024 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 27, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK.THE MANSARD ROOF SUPPORTED ON 3RDFL & MASONRY WALLS IS DETERIORATED AND COMPROMISED.THE OLD MASONRY PARAPET IS LEANING OUT IMMED DO 1.INSTALL TEMP SHORNG TO SPPORT ROOF&MANSARD ROOF FRAMNG,2 RMVE&SECURE ALL DISPLACD BRCK&LOOSE MATERIAL |
| Oct 27, 2023 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | PARTIALLY DEMOLISH (2) CHIMNEYS AT EXP 1 DOWN TO 4TH FLOOR LEVEL INSTALL TEMPORARY WEATHERPROOF WALL AT REMOVED CHIMNEYS |
| Feb 5, 2020 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 5, 2019 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERG WORK:4FL IS WD FRAME ADDITION RESTING ON PARAPETS ABOVE 3FLAND IN DANGER OF COLLAPSE PUSHING OUT THE EXTERIOR WALLS.4FL IN DISREPAIR CRACKED&DISPLACED BRICK@CHIMNEY & EXT WALLS@3FL.THERE IS A RISK OF 4FL COLLAPSE.OWNR ENGAGE PE AND IMMD INSTL SHOR TO RESUPPT PROPERTY WALLS AND FLRS/ROOF ABOVE 6FL FRAMING.WRK SUPV BY PE.FILE PRMTS W/IN 48 HOUR |
| Nov 27, 2019 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN:4 STORY+CELLAR WOOD FRAMED FLOORS AND MASONRY LOAD BEARING WALLS FROM CELLAR TO 3RD.4TH FLOOR IS IN STATE OF DISREPAIR WATER DAMGAGE NOTED THROUGHOUT.COLLAPSED CEILINGS AND OVERHEAD HAZARDS NOTED THROUGHOUT 4TH FLOOR RENDERING 4TH FLOOR UNSAFE TO OCCUPY IMMEDIATELY VACATE THE 4TH FLOOR |
| Nov 27, 2019 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERG WRK:THE 4TH FLOOR IS WOOD FRAME ADDITION RESTING ON PARAPETS ABOVE 3RD FLOOR AND IS IN DANGER OF COLLAPSE PUSHING OUT EXT WALLS.4 FLOOR IN DISREPAIR.CRACKED AND DISPLACED BRICK@CHIM&EXT WALLS@ 3 FLOOR THERE IS POTENTIAL OF COLLAPSE OF 4TH FLOOR.DEMOLISH 4TH FLOOR UNDER DIRECT & CONTINOUS SUPERVISION OF PE.STRT BY 12/2/19.FILE BY 12/4/19 |
| Nov 8, 2019 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | A EXP#1(MARCY AVE)ERECT 60 LINEAR FT OF SIDEWALK SHED &COVER THE ENTIR WIDTH OF THE FRONT YARD & PUBLIC SIDEWALK & RETURN @EXP#2(DEKALB AVE) 25 FT & COVER THE ENTIRE WIDTH OF THE SWS.AT EXP#4 ERECT 15 FT OF SIDE WALK SHED & EXTEND TO COVER THE ENTRANCE OF 671 MARCY AVENUE. IN TOTAL ERECT APPROX. 100 FT OF SIDEWALK SHED TO SAFEGUARD PUBLIC & PROPERTY |
| Mar 26, 2002 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 11, 2001 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| May 11, 2001 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 10, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 16, 1993 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |