Brooklyn East New York-New Lots
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 3-04087-0010), so they can include other buildings on the same lot.
125 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| May 5, 2026 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Jun 16, 2025 | A | NOV SENT OUT | 3F | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER , THE PRIVATE HALLWAY , THE 1st ROOM FROM EAST AT NORTH, THE KITCHEN , THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, CEILING, WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, EAST WALL IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR AT NORTH IN THE PRIVATE HALLWAY LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | C | VIOLATION CLOSED | 3F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN GLASS MIRROR AT MEDICINE CABINET ON SOUTH WALL IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER AT SOUTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | C | VIOLATION CLOSED | 3F | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION ACTIVE WATER LEAK AT WASTE DRAIN PIPE AT SINK IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BATH TUB SURFACE WITH SPRAY ENAMEL IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE BROKEN WASH BASIN IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | C | VIOLATION CLOSED | 3F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN GLASS PANE LOWER WINDOW SASH AT 1ST AND 2ND WINDOWS FROM WEST AT NORTH IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT EAST WALL IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WALL CABINET AND BASE CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2025 | B | NOV SENT OUT | 3F | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 10, 2025 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Apr 23, 2024 | A | VIOLATION DISMISSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS CEILING AND UNDER STAIR SOFFITS THROUGHOUT ALL STORIES AT PUBLIC HALL STAIRS |
| Sep 20, 2023 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED BOILER ROOM DOOR |
| Sep 20, 2023 | C | VIOLATION CLOSED | 2F | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 12, 2023 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM NO ACCESS TO BASEMENT AT BOILER ROOM |
| Sep 12, 2023 | C | VIOLATION DISMISSED | 2 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Apr 28, 2023 | B | VIOLATION DISMISSED | 1F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 28, 2023 | A | VIOLATION DISMISSED | 1F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 28, 2023 | C | VIOLATION DISMISSED | 1F | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 1, 2022 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Oct 27, 2021 | B | NOV SENT OUT | 3F | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE. IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Apr 12, 2021 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Mar 5, 2020 | C | DEFECT LETTER ISSUED | 2R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 25 SQ FT AT THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 13632919 ISSUED 05-MAR-20 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b). |
| Mar 5, 2020 | B | VIOLATION CLOSED | 2R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH AT THE 2ND WINDOW FROM WEST AT NORTH IN THE 3rd ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2020 | B | VIOLATION CLOSED | 2R | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2020 | B | VIOLATION CLOSED | 2R | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2020 | B | VIOLATION CLOSED | 2R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 25 SQ FT AT THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Dec 26, 2019 | B | VIOLATION DISMISSED | 3R | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ... LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Dec 26, 2019 | B | VIOLATION DISMISSED | 3R | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ... LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Dec 26, 2019 | C | VIOLATION CLOSED | 3R | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 29, 2019 | C | DEFECT LETTER ISSUED | 3R | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, NORTH WALL IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 29, 2019 | A | VIOLATION DISMISSED | 3R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING VENT IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 29, 2019 | B | VIOLATION CLOSED | 3R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING CEILING IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 29, 2019 | B | VIOLATION CLOSED | 3R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT NORTH WALL NORTH WALL IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 31, 2019 | B | VIOLATION CLOSED | 3R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT CEILING IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 31, 2019 | B | VIOLATION CLOSED | 3R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM IN THE PRIVATE HALLWAY LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 31, 2019 | C | VIOLATION CLOSED | 3R | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 31, 2019 | C | VIOLATION CLOSED | 3R | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Aug 9, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS THE BULKHEAD DOOR TO ROOF |
| Aug 9, 2018 | B | VIOLATION CLOSED | 1F | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR - DEFECTIVE (HARD- WIRED) UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jan 19, 2018 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR |