Brooklyn Carroll Gardens-Cobble Hill-Gowanus-Red Hook
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
10 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Dec 8, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | CORRECTIVE ACTION PLAN REQ'D-EXP1 HAS MORTAR JOINTS ERODING IN VARIOUS LOCATIONS,PARTIAL BOTTOM EDGE OF CORNICE PARTIALLY DISLODGED FROM BRICK FACADE. EXP2 SPALLING MASONRY IN VARIOUS LOCATIONS,EXP1/2 CORNER HAS A LARGE VERT CRACK. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING W/DOB&NYS TO EVAL ENTIRE BLDG&SUBMIT CORRECTIVE ACTION PLAN |
| Sep 6, 2017 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jun 20, 2017 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FM.OWNER RESP. KEEP BLDG IN SAFE COND.BRICK MASONRY FRONT WALL IN A STATE OF DISREPAIR.FRONT BRICK BULGING OUT OF PLUMB&UP TO A FOOT OUT OF PLANE,EXTREME NEAR ADJ 633 UNION ST.REMEDY:OWNER HIRE PE ENG'R TO ASSESS&REPORT COND OF ENTIRE BLDG,PREP PLANS&OBTAIN PERM FOR REPAIR BY 7/31/17.ENGAGE CONT'R TO COMP REMEDIAL WORKS BY 9/30/17 |
| Jun 20, 2017 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | FTM / SWS |
| Jun 20, 2017 | V-DOB VIOLATION - ACTIVE | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | FTM/ SWS |
| Jan 1, 2009 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Oct 30, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jan 3, 2008 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 19, 2007 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 6, 2006 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |