NYC Building Report

Brooklyn Crown Heights (South)

616 Empire Boulevard, Brooklyn

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

8 records

Date Status Type Summary
Dec 4, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN A BLDG IN A SAFE CONDITION.THE GARAGE IS LOCATD@ THE REAR OF THE LOT.THE GARAGE STRCTRE SFFRD FRM FAILURE TO MAINTAIN THE EXP2/3 WALL CRNR HAS A VERT CRCK W/SEPARATION.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER 350227 (082524FEU30903ZT)
Dec 4, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN IN A BLDG IN A SAFE CONDITION.THE GARAGE LOCATED@ THE REAR OF THE THE LOT.THE EXPLOSION DMGD WAS LOCALIZED IN THE BSMNT NEAR EXP1&EXP1/4 CRNR.THE FRNT YRD BRCK PARAPETS WERE SEV DMGD.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,PREPARE/FILE RPAIR DWGS.BLDG TO BE RPAIRD UNDR PRMT STRTNG 9/8/25&CMPLTD
Aug 25, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER.THE GARAGE LOCATED@THE REAR OF THE LOT THE EXPLOSION DMGD WAS LOCALIZED IN THE BSMNT NEAR EXP1&EXP1/4 CRNR THE FRNT YRD BRCK PARAPTS WERE SEVERELY DMGD BULGD OUTWRD,DISLOCATED.OWNR TO IMMED 1.RTAIN A NYSE&DOB REG CNTRCTR TO HAND DEMO THE FRNT YRD PARAPT TO A SAFE LVL.STRT WRK NO LATER THAN 8/26
Aug 25, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN A BLDG IN A SAFE CONDITION.THE GARAGE LOCATED@THE REAR OF THE LOT.THE EXPLOSION DMG WAS LOCALIZED IN THE BSMNT NEAR EXP1 &EXP1/4 CRNR.THE FRNT YRD BRCK PARAPETS WERE SEV DMGD.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,PREPARE/FILE RPAIR DWGS.BLDG TO BE RPAIRD UNDR PRMT STRTNG 9/8/25&CMPLTD
Aug 25, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN A BLDG IN A SAFE CONDITION.THE GARAGE IS LOCATD@ THE REAR OF THE LOT.THE GARAGE STRCTRE SFFRD FRM FAILURE TO MAINTAIN THE EXP2/3 WALL CRNR HAS A VERT CRCK W/SEPARATION.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG DTRMINE THE STRCTRL STBILITY,&PREPARE/FILE RPAIR DWGS.BLDG TOBE RPAIRED
Aug 25, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL STRUCTURE RENDERED NON COMPLIANT AT TIME OF INSPECTION DAMAGE OBSERVED TOO HAVE BEEN SUSTAINED TO ENTIRE BUILDING DUE TO EXPLOSION IN CELLAR STRUCTURE MUST BE MAINTENANCE TO CODE COMPLIANT
Aug 25, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED THE AFTERMATH OF A CELLAR EXPLOSION THAT HAS COMPROMISED ENTI RE SSTRUCTURE WITH A BLOWN OUT WALL, BUCKLE FLOORS , MASONRY CRACKS AN D BUILDING SUBMIT ENGINNERS REPORT EVALUATING THE CITED CONDTIONSWITH PHOTOS AND THE TIME FRAME TO ERTINSPECTIONS@BUILDINGS.NYC.GOV
Aug 25, 2025 V-DOB VIOLATION - ACTIVE IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL ERECT CONSTRUCTION FENCE 50 LINEAR FT AS FOLLOWS 30FT AT EXPOSURE 4 AND 20FT AT EXPOSURE 1 TO SAFEGUARD PUBLIC AND PROPERTY