Brooklyn Bay Ridge
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
13 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Apr 3, 2021 | V-DOB VIOLATION - ACTIVE | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 11, 2020 | V-DOB VIOLATION - ACTIVE | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 5, 2019 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST |
| Mar 25, 2019 | V-DOB VIOLATION - ACTIVE | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 28, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 3, 2015 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 1, 2012 | V-DOB VIOLATION - ACTIVE | EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST |
| Dec 20, 2011 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 3, 2009 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO PROVIDE ADEQUATE HOUSEKEEPING. DEBRIS THROUGHOUT SITE. MA TERIAL STORED TOO CLOSE TO EDGE OF BLDG REMEDY: STOP ALL WORK. PROVIDE ADEQUATE HOUSEKEEPING. CALL SEPEX FO R REINSPECTION |
| Dec 19, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | INADEQUATE DETAILS ON APPROVED PLANS FOR: TEMPORARY SHORING DURING REM OVAL OF EXISTING FLOORS/STAIRS. MAINTENANCE/BRACING OF WALLS BETWEEN F LOOR REMOVAL & NEW FLOOR JOIST INSTALLATION. JOIST ANCHORAGE IN MASONR Y WALLS. REMEDY: PROVIDE ENGINEER SHOP DRAWINGS WITH ABOVE DETAILS. PR OVIDE TR-1 FOR SPECIAL INSTRUCTION FOR SHORING & STRUCTURAL STABLIITY |
| Jun 18, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | INADEQUATE PLANS FOR UNDERPINNING SHEETING SHORING BRACING ALT1 PERMIT #302254708 NO UNDERPINNING LAYOUT OR DETAILS ON PLANS AMENDED 2/7/08 FOR EXCAVATION APPROX 1 TO 9 FEET BELOW EXISTING FOUNDATIONS VERTICAL FOUNDATION DIMENSIONS NOT ON PLANS NO SHORING LAYOUT OR DESIGN AT APPR OX 12 FOOT DEEP REMEDY: STOP ALL WORK BACKFILL SUPPORT ADJOINING GROUN |
| Jun 18, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK WITH OUT A PERMIT NOTED: AT TIME OF INSPECTION EXCAVATING FOR NEW CELLAR INTERIOR DEMOLITION AND CONCRETE UNDERPINNING AND WALLS IN PROGRESS REMEDY: STOP ALL WORK OBTAIN A POST PERMIT THEN CALL SEP/EX 212 676-29 18 |
| Jun 13, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STOP ALL WORK IMMEDIATELY,EXCEPT TO PROVIDE PROTECTION |